SCHNEIDER
RCCB with re-closer - RED - 4 poles - 60 A - class A - 30 mA - 18268
18268
€466.53 Excl. Tax
€559.84 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | RED |
---|---|
Range: | Acti 9 |
Product or component type: | Residual current circuit breaker (RCCB) |
Device short name: | REDs |
Protection type: | Recloser |
Poles description: | 4P |
Neutral position: | Left |
Signal contacts composition: | 1NO or 1NC or intermittent 1 Hz |
[In] rated current: | 63 A |
Earthing system: | TTTN-S |
Network type: | AC |
Earth-leakage sensitivity: | 30 mA |
Device location in system: | Outgoer |
---|---|
Network frequency: | 50 Hz |
[Ue] rated operational voltage: | 400 V AC 50 Hz phase to neutral |
Reset: | Fault reset earth leakage |
Test function: | Manual at > 170 V |
Earth-leakage protection time delay: | Instantaneous |
Earth-leakage protection class: | Type A |
Minimum leakage resistance: | 16 kOhm at operating8 kOhm at non-operating |
[Im] rated making and breaking capacity: | Idm 630 A 400 V |
Rated conditional short-circuit current: | Inc: 10 kA - associated with C120H, 63 AInc: 10 kA - associated with iC60N, 63 AInc: 15 kA - associated with NG125, 25 AInc: 10 kA - associated with iC60H, 63 AInc: 15 kA - associated with iC60H, 25 AInc: 10 kA - associated with iC60L, 63 AInc: 25 kA - associated with gG fuse, 25 AInc: 10 kA - associated with C120N, 63 AInc: 10 kA - associated with NG125, 63 AInc: 15 kA - associated with gG fuse, 40 AInc: 10 kA - associated with C120L, 63 AInc: 10 kA - associated with gG fuse, 63 AInc: 15 kA - associated with iC60L, 25 A |
[Ui] rated insulation voltage: | 500 V |
[Uimp] rated impulse withstand voltage: | 4 kV |
Surge current: | 250 A |
Control type: | Toggle |
Local signalling: | 2 LEDsResidual current device |
Operating mode: | Reclosing time: Max nb of consecutive restart: 3Min interval between 2 closings: 30 sStopping restart cycle if insulation fault present: 15 minInsulation fault presence monitoring |
Insulation fault diagnosis: | If fault detected, diagnosis every 2 minutes |
Signalling circuit voltage: | AC: 5...230 VDC: 5...230 V |
Signalling output current: | 0.6 mA min100 mA max, cos phi =1 |
Mounting mode: | Fixed |
Mounting support: | 35 mm symmetrical DIN rail |
9 mm pitches: | 14 |
Height: | 98 mm |
Width: | 125 mm |
Depth: | 79.5 mm |
Embedding depth: | 73.5 mm |
Product weight: | 0.72 kg |
Mechanical durability: | 4000 cycles open-close |
Connections - terminals: | Guard tunnel terminal 35 mm² rigidGuard tunnel terminal 35 mm² flexibleGuard tunnel terminal 35 mm² flexible with ferrule |
Auxiliary connection terminal: | Tunnel type terminal in 2.5 mm² flexibleTunnel type terminal in 2.5 mm² rigidTunnel type terminal in 2.5 mm² flexible with ferrule |
Wire stripping length: | Power circuit: 12 mmSignaling: 9 mm |
Tightening torque: | Power circuit: 2 N.mSignaling: 0.4 N.m |
Market segment: | Small commercial |
Compatibility code: | REDs |
In short
Reference 18268
Product Name RCCB with re-closer - RED - 4 poles - 60 A - class A - 30 mA - 18268
Range Acti 9
Related Categories