SCHNEIDER
residual current protection relay, Vigirex RH197P, 30 mA to 30 A, 220/240 VAC 50/60Hz, alarm 50%, front panel mounting - 56507
56507
€276.95 Excl. Tax
€332.34 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | VigiPacT |
---|---|
Device short name: | RH197P |
Product or component type: | Residual current protection relay |
Relay application: | Protection relay |
Mounting support: | Front panel |
Earth-leakage protection class: | Type A |
Type of setting: | Selector |
Residual earth-leakage sensitity adjustment type: | Adjustable 19 settings |
Earth leakage current: | 0.03...30 A |
Residual earth-leakage time delay adjustment type: | Instantaneous for 0.03 AAdjustable 7 settings 0...4.5 s for 0.03...30 A |
Alarm threshold: | 50 % |
Range compatibility: | TOA earth leakage current sensor A earth leakage current sensor L earth leakage current sensor |
[Ithe] conventional enclosed thermal current: | 8 A |
Minimum load: | 10 mA at 12 V |
[Us] rated supply voltage: | 220...240 V AC 50/60 Hz 70...110 % |
Power consumption in VA: | 4 VA |
Network rated voltage: | 1000 V - AC at 50/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum) |
Earthing system: | ITTTTN-S |
[Uimp] rated impulse withstand voltage: | 8 kV |
Reset: | Manual resetAutomatic reset |
Test function: | LocalRemote test |
---|---|
Monitoring: | Electronics (watchdog) Power supply (continuous) Relay/sensor link (continuous) |
Signal contacts composition: | 1 NO |
Type of measurement: | Earth fault current internal measurement, range: 80...100 % |
Refresh time: | 0.5 s |
Tamperproof of settings: | Protected by sealable cover |
Connections - terminals: | Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Auxiliary power supply: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Auxiliary power supply: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Fault: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Fault: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Fault: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Relay test and fault reset: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Sensor: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Sensor: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Sensor: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.2...2.5 mm² flexible AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.2...2.5 mm² rigid AWG 24...AWG 12Voltage presence: terminal block cable(s) 0.25...2.5 mm² flexible AWG 24...AWG 12 |
Wire stripping length: | Auxiliary power supply: 7 mmFault: 7 mmRelay test and fault reset: 7 mmSensor: 7 mmVoltage presence: 7 mm |
Tightening torque: | Auxiliary power supply: 0.6 N.mFault: 0.6 N.mRelay test and fault reset: 0.6 N.mSensor: 0.6 N.mVoltage presence: 0.6 N.m |
Width: | 72 mm |
Height: | 72 mm |
Depth: | 92 mm |
Cut-out dimensions: | 68 x 68 mm |
Product weight: | 0.3 kg |
IP degree of protection: | IP40 on front face: conforming to EN/IEC 60529IP30 on side parts: conforming to EN/IEC 60529IP20 on connection terminals: conforming to EN/IEC 60529 |
IK degree of protection: | IK07 conforming to EN 50102 |
Mechanical robustness: | Fire resistance conforming to IEC 60695-2-1IK protection 2 joules: IK07 conforming to EN 50102Vibrations 13.2...100 Hz: 0.7 gVibrations 2...13.2 Hz: +/- 1 mm |
Compatibility code: | RH197P |
In short
Reference 56507
Product Name residual current protection relay, Vigirex RH197P, 30 mA to 30 A, 220/240 VAC 50/60Hz, alarm 50%, front panel mounting - 56507
Range Vigirex
Related Categories