Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Acti9 iC60 RCBO - 2P - 20 A - C Curve - 10000A/15kA - 30 mA - A type - A9D17220

A9D17220

€101.27 Excl. Tax
€121.52 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: Acti 9
Range: Acti 9
Product name: Acti 9 iC60 RCBO
Product or component type: Residual current breaker with overcurrent protection (RCBO)
Device short name: IC60 RCBO
Device application: Distribution
Poles description: 2P
Number of protected poles: 2
[In] rated current: 20 A
Network type: AC
Trip unit technology: Thermal-magnetic
Curve code: C
Earth-leakage sensitivity: 30 mA
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A
Breaking capacity: 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-115 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Suitability for isolation: No conforming to IEC 60947-1
Quality labels: NFKEMA-KEURIMQVDE
Device location in system: Outgoer
Network frequency: 50 Hz
[Ue] rated operational voltage: 220...240 V AC 50 Hz
Magnetic tripping limit: 5...10 x In
Residual current tripping technology: Voltage independent
[Ics] rated service breaking capacity: 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-17.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity: Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class: 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage: 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage: 4 kV
Surge current: 250 A
Contact position indicator: No
Control type: Toggle
Local signalling: ON, OFF, fault trip
Mounting mode: Clip-on
Mounting support: DIN rail
Comb busbar and distribution block compatibility: Top or bottom: YESBottom: biconnect
9 mm pitches: 4
Height: 86 mm
Width: 36 mm
Depth: 78 mm
Product weight: 273 g
Colour: White
Mechanical durability: 20000 cycles
Electrical durability: 10000 cycles
Connections - terminals: Tunnel type terminal top or bottom 1...35 mm² rigidTunnel type terminal top or bottom 1...25 mm² flexibleTunnel type terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length: 12 mm for top or bottom connection
Tightening torque: 2 N.m
Earth-leakage protection: Integrated
In short
Reference A9D17220
Product Name Acti9 iC60 RCBO - 2P - 20 A - C Curve - 10000A/15kA - 30 mA - A type - A9D17220
Range Acti 9
Related Categories