Technical informations
Range: Acti9
Product name: Acti9 iCV40
Product or component type: Residual current breaker with overcurrent protection (RCBO)
Device short name: ICV40N
Device application: Distribution
Poles description: 1P + N
Number of protected poles: 1
Neutral position: Left
[In] rated current: 20 A
Network type: AC
Trip unit technology: Thermal-magnetic
Curve code: C
Earth-leakage sensitivity: 30 mA
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A
Breaking capacity: 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Quality labels: VDEOVERCMKEMA-KEUREAC
Device location in system: Outgoer
Network frequency: 50/60 Hz
[Ue] rated operational voltage: 230 V AC 50/60 Hz
Magnetic tripping limit: 5...10 x In
Residual current tripping technology: Voltage independent
[Ics] rated service breaking capacity: 6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacity: Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1
Limitation class: 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage: 400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 4 kV
Contact position indicator: Yes
Control type: Toggle
Local signalling: ON/OFF indicationFault indication
Mounting mode: Clip-on
Mounting support: DIN rail
Comb busbar and distribution block compatibility: Top or bottom: tooth
9 mm pitches: 4
Height: 85 mm
Width: 36 mm
Depth: 73 mm
Net weight: 210 g
Colour: White
Mechanical durability: 20000 cycles
Electrical durability: 20000 cycles
Locking options description: SealablePadlocking device
Connections - terminals: Tunnel type terminals top or bottom 1...16 mm² rigidTunnel type terminals top or bottom 1...10 mm² flexible
Wire stripping length: 14 mm for top or bottom connection
Tightening torque: 2 N.m top or bottom
Earth-leakage protection: Integrated
Compatibility code: ICV40N