SCHNEIDER
Acti9 iDD40N TG - RCBO - 1P+N - 20A - C Curve - 6000A/10kA - 300mA - type AC - A9DV7620
A9DV7620
€125.59 Excl. Tax
€150.71 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | Acti9 |
---|---|
Product name: | Acti9 iDD40 TG |
Product or component type: | Residual current breaker with overcurrent protection (RCBO) |
Device short name: | IDD40N TG |
Device application: | Distribution |
Poles description: | 1P + N |
Number of protected poles: | 1 |
Neutral position: | Left |
[In] rated current: | 20 A |
Network type: | AC |
Trip unit technology: | Thermal-magnetic |
Curve code: | C |
Earth-leakage sensitivity: | 300 mA |
Earth-leakage protection time delay: | Instantaneous |
Earth-leakage protection class: | Type AC |
Breaking capacity: | 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-110 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
Quality labels: | NF |
Device location in system: | Group incomer |
---|---|
Network frequency: | 50 Hz |
[Ue] rated operational voltage: | 230 V AC 50 Hz |
Magnetic tripping limit: | 5...10 x In |
Residual current tripping technology: | Voltage independent |
[Ics] rated service breaking capacity: | 6000 A 100 % x Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-17.5 kA 75 % x Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
Rated breaking and making capacity: | Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
Limitation class: | 3 conforming to EN/IEC 61009-2-1 |
[Ui] rated insulation voltage: | 400 V AC 50 Hz |
[Uimp] rated impulse withstand voltage: | 4 kV |
Contact position indicator: | Yes |
Control type: | Toggle |
Local signalling: | ON/OFF indicationTrip indicator |
Mounting mode: | Clip-on |
Mounting support: | DIN rail |
Comb busbar and distribution block compatibility: | Top or bottom: tooth |
9 mm pitches: | 4 |
Height: | 91 mm |
Width: | 36 mm |
Depth: | 73 mm |
Product weight: | 215 g |
Colour: | White |
Mechanical durability: | 20000 cycles |
Electrical durability: | 20000 cycles |
Locking options description: | SealablePadlocking device |
Connections - terminals: | Tunnel type terminals top or bottom 1...16 mm² rigidTunnel type terminals top or bottom 1...10 mm² flexible |
Wire stripping length: | 14 mm for top or bottom connection |
Tightening torque: | 2 N.m top or bottom |
Earth-leakage protection: | Integrated |
In short
Reference A9DV7620
Product Name Acti9 iDD40N TG - RCBO - 1P+N - 20A - C Curve - 6000A/10kA - 300mA - type AC - A9DV7620
Range Acti9
Device function Distribution