Technical informations
Device application: | Distribution |
---|---|
Range: | Acti 9 |
Product name: | Acti 9 iC60 |
Product or component type: | Miniature circuit-breaker |
Device short name: | IC60N |
Poles description: | 2P |
Number of protected poles: | 2 |
[In] rated current: | 6 A |
Network type: | ACDC |
Trip unit technology: | Thermal-magnetic |
Curve code: | C |
Breaking capacity: | 6 kA Icu conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz10 kA Icu conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz20 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz6000 A Icn conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz36 kA Icu conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz10 kA Icu conforming to EN/IEC 60947-2 - <= 125 V DC36 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz |
Utilisation category: | Category A conforming to EN 60947-2Category A conforming to IEC 60947-2 |
Suitability for isolation: | Yes conforming to EN 60947-2Yes conforming to IEC 60947-2Yes conforming to EN 60898-1Yes conforming to IEC 60898-1 |
Standards: | EN 60898-1EN 60947-2IEC 60898-1IEC 60947-2 |
Network frequency: | 50/60 Hz |
---|---|
Magnetic tripping limit: | 8 x In +/- 20 % |
[Ics] rated service breaking capacity: | 6000 A 100 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz10 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC10 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC6000 A 100 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz4.5 kA 75 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz15 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz4.5 kA 75 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz15 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz27 kA 75 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz27 kA 75 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz |
Limitation class: | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
[Ui] rated insulation voltage: | 500 V AC 50/60 Hz conforming to IEC 60947-2500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
Contact position indicator: | Yes |
Control type: | Toggle |
Local signalling: | Trip indicator |
Mounting mode: | Fixed |
Mounting support: | DIN rail |
Comb busbar and distribution block compatibility: | YES top or bottom |
9 mm pitches: | 4 |
Height: | 85 mm |
Width: | 36 mm |
Depth: | 78.5 mm |
Product weight: | 0.25 kg |
Colour: | White |
Mechanical durability: | 20000 cycles |
Electrical durability: | 10000 cycles |
Connections - terminals: | Single terminal, top or bottom rigid wire(s) 1...25 mm² maxSingle terminal, top or bottom flexible wire(s) 1...16 mm² max |
Wire stripping length: | 14 mm top or bottom |
Tightening torque: | 2 N.m top or bottom |
Earth-leakage protection: | Separate block |