Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
100 products at 10% off until 18 November! Find out more
SCHNEIDER

Miniature circuit-breaker, Acti9 iC60L, 2P, 20 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2) - A9F94220

A9F94220

€57.48 Excl. Tax
€68.98 Inc. Tax
available In stock more than 100 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Device application: Distribution
Range: Acti 9
Range of product: IC60
Product name: Acti 9 iC60
Product or component type: Miniature circuit-breaker
Device short name: IC60L
Poles description: 2P
Number of protected poles: 2
[In] rated current: 20 A
Network type: DCAC
Trip unit technology: Thermal-magnetic
Curve code: C
Breaking capacity code: L
Breaking capacity: 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-150 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-270 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-270 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-220 kA Icu at 20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-225 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category: Category A conforming to EN 60947-2Category A conforming to IEC 60947-2
Suitability for isolation: Yes conforming to EN 60898-1Yes conforming to EN 60947-2Yes conforming to IEC 60898-1Yes conforming to IEC 60947-2
Standards: IEC 60898-1EN 60947-2IEC 60947-2EN 60898-1
Network frequency: 50/60 Hz
[Ue] rated operational voltage: 220...240 V AC 50/60 Hz400 V AC 50/60 Hz380...415 V AC 50/60 Hz440 V AC 50/60 Hz12...133 V AC 50/60 Hz72...125 V DC
Magnetic tripping limit: 8 x In +/- 20 %
[Ics] rated service breaking capacity: 12.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz10 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz12.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz10 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz25 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz25 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz35 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz35 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz7500 A 50 % conforming to EN 60898-1 - 400 V AC 50/60 Hz7500 A 50 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz20 kA 100 % conforming to EN 60947-2 - 72...125 V DC20 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
Limitation class: 3 conforming to EN 60898-13 conforming to IEC 60898-1
[Ui] rated insulation voltage: 500 V AC 50/60 Hz conforming to EN 60947-2500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2
Contact position indicator: Yes
Control type: Toggle
Local signalling: Trip indicator
Mounting mode: Fixed
Mounting support: DIN rail
Comb busbar and distribution block compatibility: Top or bottom: YES
9 mm pitches: 4
Height: 85 mm
Width: 36 mm
Depth: 78.5 mm
Product weight: 0.25 kg
Colour: White
Mechanical durability: 20000 cycles
Electrical durability: 10000 cycles
Connections - terminals: Single terminal (top or bottom) 1...25 mm² rigidSingle terminal (top or bottom) 1...16 mm² flexible
Wire stripping length: 14 mm for top or bottom connection
Tightening torque: 2 N.m top or bottom
Earth-leakage protection: Separate block
Compatibility code: IC60
Market segment: Small commercialResidential
In short
Reference A9F94220
Product Name Miniature circuit-breaker, Acti9 iC60L, 2P, 20 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2) - A9F94220
Range Acti 9
Device function Distribution
Related Categories