Technical informations
Range: | Acti9 |
---|---|
Product name: | Acti9 iDT40 |
Product or component type: | Miniature circuit-breaker |
Device short name: | IDT40N |
Device application: | Distribution |
Poles description: | 1P + N |
Number of protected poles: | 1 |
Neutral position: | Left |
[In] rated current: | 16 A |
Network type: | AC |
Trip unit technology: | Thermal-magnetic |
Curve code: | C |
Breaking capacity code: | N |
Breaking capacity: | 6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-110 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
Quality labels: | NF |
Network frequency: | 50 Hz |
---|---|
[Ue] rated operational voltage: | 230 V AC 50 Hz |
Magnetic tripping limit: | 5...10 x In conforming to EN/IEC 60898-18 x In +/- 20 % conforming to EN/IEC 60947-2 |
[Ics] rated service breaking capacity: | 6000 A 100 % x Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-17.5 kA 75 % x Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
Limitation class: | 3 conforming to EN/IEC 60898-1 |
[Ui] rated insulation voltage: | 400 V AC 50 Hz conforming to EN/IEC 60947-2 |
[Uimp] rated impulse withstand voltage: | 4 kV conforming to EN/IEC 60947-2 |
Contact position indicator: | Yes |
Control type: | Toggle |
Local signalling: | ON/OFF indication |
Mounting mode: | Clip-on |
Mounting support: | DIN rail |
9 mm pitches: | 2 |
Height: | 85 mm |
Width: | 18 mm |
Depth: | 74 mm |
Product weight: | 120 g |
Colour: | White |
Mechanical durability: | 20000 cycles |
Electrical durability: | 20000 cycles |
Locking options description: | Padlocking device |
Top connection: | Screw |
Bottom connection: | Screw |
Connections - terminals: | Tunnel type terminals top or bottom 1...10 mm² flexibleTunnel type terminals top or bottom 1...16 mm² rigid |
Wire stripping length: | 14 mm for top or bottom connection |
Tightening torque: | 2 N.m top or bottom |
Earth-leakage protection: | Separate block |
Compatibility code: | IDT40N |
In short
Reference A9P24616
Product Name Miniature circuit-breaker, Acti9 iDT40N, 1P+N, 16 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) - A9P24616
Range Acti9
Device function Distribution
Related Categories