Technical informations
Range of product: | Altivar Machine ATV340 |
---|---|
Product or component type: | Variable speed drive |
Product specific application: | Machine |
Variant: | Standard version |
Design of frequency changer: | U converter |
Mounting mode: | Cabinet mount |
Communication port protocol: | Modbus serial |
Option card: | Communication module, Profibus DP V1Communication module, ProfinetCommunication module, DeviceNetCommunication module, CANopenCommunication module, EtherCAT |
Network number of phases: | 3 phases |
Supply frequency: | 50...60 Hz +/- 5 % |
[Us] rated supply voltage: | 380...480 V - 15...10 % |
[Us] rated supply voltage: | 380...480 V |
Relative symmetric mains voltage tolerance: | 10 % |
Relative symmetric network frequency tolerance: | 5 % |
Nominal output current: | 12.7 A |
Number of input phases: | 3 |
Number of output phases: | 3 |
Motor power kW: | 7.5 kW for normal duty5.5 kW for heavy duty |
Motor power hp: | 10 hp for normal duty7 hp for heavy duty |
EMC filter: | Class C3 EMC filter integrated |
IP degree of protection: | IP20 |
Discrete input number: | 5 |
---|---|
Discrete input type: | PTI programmable as pulse input: 0...30 kHz, 24 V DC (30 V)DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm programmable |
Discrete input logic: | 16 preset speeds |
Discrete output number: | 2.0 |
Discrete output type: | Programmable output DQ1, DQ2 30 V DC 100 mA |
Analogue input number: | 2 |
Analogue input type: | AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI1 software-configurable temperature probe or water level sensorAI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bitsAI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
Analogue output number: | 2 |
Analogue output type: | Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSoftware-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits |
Relay output number: | 2 |
Relay output type: | Relay outputs R1ARelay outputs R1C electrical durability 100000 cyclesRelay outputs R2ARelay outputs R2C electrical durability 100000 cycles |
Output voltage: | |
Number of inputs, bidirectional, not potential-free: | 0 |
Number of inputs, potential-free: | 0 |
Maximum switching current: | Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1C on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCRelay output R2C on resistive load, cos phi = 1: 5 A at 250 V ACRelay output R2C on resistive load, cos phi = 1: 5 A at 30 V DCRelay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Minimum switching current: | Relay output R1B: 5 mA at 24 V DCRelay output R2C: 5 mA at 24 V DC |
Encoder protocol: | 1 VppEnDat 2.2ResolverRS 422SSI 24VSSI 5VTTL/HTL |
Computer port: | True |
Optical interface present: | False |
Physical interface: | 2-wire RS 485 |
Connector type: | 1 RJ45 |
Method of access: | Slave Modbus RTU |
Transmission rate: | 4.8 kbit/s9.6 kbit/s19.2 kbit/s38.4 kbit/s |
Transmission frame: | RTU |
Number of addresses: | 1...247 |
Data format: | 8 bits, configurable odd, even or no parity |
Type of polarization: | No impedance |
Number of HW interfaces parallel: | 0 |
Number of HW interfaces industrial Ethernet: | 0 |
Number of HW interfaces PROFINET: | 0 |
Number of HW interfaces serial RS232: | 0 |
Number of HW interfaces serial RS422: | 0 |
Number of HW interfaces serial RS485: | 1 |
Number of HW interfaces serial TTY: | 0 |
Number of HW interfaces USB: | 0 |
Number of HW interfaces other: | 0 |
Supporting protocol for AS-Interface Safety at Work: | False |
Supporting protocol for ASI: | False |
Supporting protocol for SUCONET: | False |
Supporting protocol for BACnet: | False |
Supporting protocol for CAN: | True |
Supporting protocol for Data-Highway: | False |
Supporting protocol for DeviceNet: | False |
Supporting protocol for DeviceNet Safety: | False |
Supporting protocol for EtherNet/IP: | False |
Supporting protocol for Foundation Fieldbus: | False |
Supporting protocol for INTERBUS: | False |
Supporting protocol for INTERBUS-Safety: | False |
Supporting protocol for KNX: | False |
Supporting protocol for LON: | False |
Supporting protocol for MODBUS: | True |
Supporting protocol for other bus systems: | True |
Supporting protocol for PROFIBUS: | True |
Supporting protocol for PROFINET CBA: | True |
Supporting protocol for PROFINET IO: | True |
Supporting protocol for PROFIsafe: | False |
Supporting protocol for SafetyBUS P: | False |
Supporting protocol for SERCOS: | False |
Supporting protocol for TCP/IP: | False |
4 quadrant operation possible: | True |
Asynchronous motor control profile: | Variable torque standardOptimized torque modeConstant torque standard |
Pollution degree: | 2 conforming to EN/IEC 61800-5-1 |
Synchronous motor control profile: | Permanent magnet motorReluctance motor |
Maximum output frequency: | 0.599 kHz |
Acceleration and deceleration ramps: | Linear adjustable separately from 0.01...9999 sS, U or customized |
Motor slip compensation: | AdjustableAutomatic whatever the loadCan be suppressedNot available in permanent magnet motor law |
Switching frequency: | 2...16 kHz adjustable7...16 kHz with derating factor |
Nominal switching frequency: | 4 kHz |
Speed drive output frequency: | 0.1...599 Hz |
Braking to standstill: | By DC injection |
Brake chopper integrated: | True |
Line current: | 15.3 A at 380 V (normal duty)12.2 A at 480 V (normal duty)20.0 A at 380 V (heavy duty)16.0 A at 480 V (heavy duty)11.6 A at 380 V with external line choke (heavy duty)9.4 A at 480 V with external line choke (heavy duty) |
Maximum associated fuse rating: | 40.0 A |
Maximum input current: | 20.0 A |
Maximum output voltage: | 480 V |
Nominal output power: | 5.5 W |
Apparent power: | 12.1 kVA at 480 V (normal duty)13.3 kVA at 480 V (heavy duty) |
Maximum transient current: | 18.2 A during 60 s (normal duty)19.1 A during 60 s (heavy duty)22.3 A during 2 s (normal duty)22.9 A during 2 s (heavy duty) |
Electrical connection: | Screw terminal, clamping capacity: 4...6 mm² for DC busScrew terminal, clamping capacity: 0.2...2.5 mm² for controlScrew terminal, clamping capacity: 1.5...6 mm² for line sideScrew terminal, clamping capacity: 1.5...6 mm² for motor |
Capacity of DC link: | 750.0 µF |
Network frequency: | 50...60 Hz |
Prospective line Isc: | 22 kA |
1 phase low current possible: | False |
Base load current at high overload: | 12.7 A |
Base load current at low overload: | 16.5 A |
Application in domestic and commercial area permitted: | False |
Application in industrial area permitted: | True |
EMC limit value (complied): | True |
Power loss per device current dependent: | 196.0 W |
Power loss static current independent: | 16.0 W |
Power dissipation in W: | Natural convection: 134 W at 380 V, switching frequency 4 kHz (heavy duty)Forced convection: 134 W at 380 V, switching frequency 4 kHz (heavy duty)Natural convection: 164 W at 380 V, switching frequency 4 kHz (normal duty)Forced convection: 164 W at 380 V, switching frequency 4 kHz (normal duty) |
Housing material: | Plastic |
With safety function Safely Limited Speed (SLS): | True |
With safety function Safe brake management (SBC/SBT): | True |
With safety function Safe Operating Stop (SOS): | False |
With safety function Safe Position (SP): | False |
With safety function Safe programmable logic: | False |
With safety function Safe Speed Monitor (SSM): | False |
With safety function Safe Stop 1 (SS1): | True |
With sft fct Safe Stop 2 (SS2): | False |
With safety function Safe torque off (STO): | True |
With safety function Safely Limited Position (SLP): | False |
With safety function Safe Direction (SDI): | False |
Protection type: | Thermal protection: motorSafe torque off: motorMotor phase loss: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent: driveOutput overcurrent between motor phase and earth: driveOutput overcurrent between motor phases: driveShort-circuit between motor phase and earth: driveShort-circuit between motor phases: driveMotor phase loss: driveDC Bus overvoltage: driveLine supply overvoltage: driveLine supply undervoltage: driveInput supply loss: driveExceeding limit speed: driveBreak on the control circuit: drive |
Operating element present: | True |
Width: | 110.0 mm |
Height: | 270.0 mm |
Depth: | 234.0 mm |
Product weight: | 2.9 kg |
Specific application: | Machine |
Motor starter type: | Variable speed drive |
Accuracy: | +/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input+/- 1 % AQ1 for a temperature variation 60 °C analog output |
Connector type: | connector(s)1 x RJ45, Modbus serial on front face connector(s)1 x RJ45, Modbus serial for HMI on front face |
Discrete input logic: | Positive logic (source) (DI1...DI5), 11 V (state 1)Negative logic (sink) (DI1...DI5), > 16 V (state 0), Positive logic (source) (PTI), 2.5 V (state 1)Positive logic (source) (STOA, STOB), 11 V (state 1) |
Input compatibility: | DI1...DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2PTI: pulse input level 1 PLC conforming to IEC 65A-68STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Input/output type: | Programmable as logic input/output DQ1: 0...1 kHz, Programmable as logic input/output DQ2: 0...1 kHz, |
Continuous output current: | 16.5 A at 4 kHz for normal duty12.7 A at 4 kHz for heavy duty |
Sampling duration: | 2 ms +/- 0.5 ms (DI1...DI5) - discrete input5 ms +/- 1 ms (PTI) - pulse input1 ms +/- 1 ms (AI1, AI2) - analog input5 ms +/- 1 ms (AQ1) - analog output2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output |
Refresh time: | Relay output (R1, R2): 5 ms (+/- 0.5 ms) |
Safety function: | STO (safe torque off) SIL 3 |
Vibration resistance: | 1.5 mm peak to peak (f= 2...19 Hz) conforming to EN/IEC 60721-3-3 class 3M31 gn (f= 9...200 Hz) conforming to EN/IEC 60721-3-3 class 3M3 |
Discrete and process manufacturing: | Tower crane HoistingOther application HoistingGrouping conveyor Material handlingPalletizer - high performance Material handlingCutting - high accuracy Material working (wood, ceramic, stone, pvc, metal)Polishing Material working (wood, ceramic, stone, pvc, metal)Grinding Material working (wood, ceramic, stone, pvc, metal)Slitter Material working (wood, ceramic, stone, pvc, metal)Filling bottles - synchronized operation PackagingFeed conveyor - medium performance PackagingGrouping boxing PackagingConveyor PackagingElevator PackagingOther application PackagingStandard crane - hoist HoistingAutomatic storage / retrieval system Material handlingShrinking wrapping Packaging |
In short