SCHNEIDER
soft starter, Altistart 480, 790A, 208 to 690V AC, control supply 110 to 230V AC - ATS480D88Y
ATS480D88Y
€1,594.80 Excl. Tax
€1,913.76 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Altivar Soft Starter ATS480 |
---|---|
Product or component type: | Soft starter |
Product destination: | Asynchronous motors |
Product specific application: | Process and infrastructures |
Device short name: | ATS480 |
Network number of phases: | 3 phases |
Utilisation category: | AC-3AAC-53A |
[Us] rated supply voltage: | 208...690 V - 15...10 % |
Supply frequency: | 50...60 Hz - 20...20 % |
[Ie] rated operational current: | Normal duty: 88.0 A (at |
Maximum permanent current: | 75.0 A at 40 °C for heavy duty |
Torque control: | True |
IP degree of protection: | IP20 |
Motor power kW: | 22.0 kW at 230 V in the motor supply line normal duty18.5 kW at 230 V in the motor supply line heavy duty45.0 kW at 400 V in the motor supply line normal duty37.0 kW at 400 V in the motor supply line heavy duty45.0 kW at 440 V in the motor supply line normal duty37.0 kW at 440 V in the motor supply line heavy duty55.0 kW at 500 V in the motor supply line normal duty45.0 kW at 500 V in the motor supply line heavy duty55.0 kW at 525 V in the motor supply line normal duty45.0 kW at 525 V in the motor supply line heavy duty75.0 kW at 660 V in the motor supply line normal duty55.0 kW at 660 V in the motor supply line heavy duty75.0 kW at 690 V in the motor supply line normal duty55.0 kW at 690 V in the motor supply line heavy duty45.0 kW at 230 V to the motor delta terminals normal duty37.0 kW at 230 V to the motor delta terminals heavy duty75.0 kW at 400 V to the motor delta terminals normal duty55.0 kW at 400 V to the motor delta terminals heavy duty |
Motor power hp: | 25.0 hp at 208 V normal duty20.0 hp at 208 V heavy duty30.0 hp at 230 V normal duty25.0 hp at 230 V heavy duty60.0 hp at 460 V normal duty50.0 hp at 460 V heavy duty75.0 hp at 575 V normal duty60.0 hp at 575 V heavy duty |
Option card: | Communication module for Profibus DP V1Communication module for PROFINETCommunication module for Modbus TCP/EtherNet/IPCommunication module for CANopen daisy chainCommunication module for CANopen Sub-DCommunication module for CANopen open style |
Device connection: | In the motor supply lineTo the motor delta terminals |
---|---|
[Uc] control circuit voltage: | 110...230 V AC 50/60 Hz - 15...10 % |
Apparent power: | 0.09 kVA |
Integrated motor overload protection: | True |
Accuracy class: | Class 10E |
Protection type: | Phase failure: lineIntegrated thermal protection: motorThermal protection: starterCurrent overload: motorUnderload: motorExcessive starting time, locked rotor: motorMotor phase loss: motorLine supply phase loss: lineLine supply phase loss: motorThermal protection: motor |
Output current drift: | 150...700 % |
Rated current pwr loss specification: | 88.0 A |
Power loss static current independent: | 25.0 W |
Power loss per device current dependent: | 270.0 W |
Standards: | EN/IEC 60947-4-2UL 60947-4-2IEC 60664-1 |
Product certifications: | CEcULusCCCUKCARCMEACDNVABSBVCCS |
Marking: | CECCCUKCAEACRCMCULus |
Discrete input number: | 4 |
Discrete input type: | (STOP) logic inputs, 3500 Ohm (RUN) logic inputs, 3500 Ohm (DI3) programmable as logic input, 3500 Ohm (DI4) programmable as logic input, 3500 Ohm |
Input compatibility: | STOP: discrete input level 1 PLC conforming to EN/IEC 61131-2RUN: discrete input level 1 PLC conforming to EN/IEC 61131-2DI3: discrete input level 1 PLC conforming to EN/IEC 61131-2DI4: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Discrete input logic: | Programmable digital input at State 0: |
Relay output number: | 3 |
Relay output type: | Relay outputs R1A 1 NORelay outputs R1B 1 NORelay outputs RIC NO/NC programmable |
Minimum switching current: | 10 mA at 24 V DC for relay outputs |
Maximum switching current: | Relay outputs 2 A at 250 V ACRelay outputs 2 A at 30 V DCRelay outputs |
Discrete output number: | 2 |
Discrete output type: | (DQ1) programmable digital output (DQ2) programmable digital output |
Output compatibility: | Open collector level 1 PLC conforming to IEC 65A-68 |
Analogue input number: | 1 |
Analogue input type: | AI1/PTC PTC/Pt 100 temperature probePTC2 PTC/Pt 100 temperature probePTC3 PTC/Pt 100 temperature probe |
Analogue output number: | 1 |
Analogue output type: | Current output AQ1: 0...20 mA or 0...10 V, impedance |
Communication port protocol: | Modbus serial |
Connector type: | 1 RJ45 |
Communication data link: | Serial |
Physical interface: | 2-wire RS 485 |
Transmission rate: | 1200...256000 bit/s |
Transmission frame: | RTU |
Data format: | 8 bits, configurable odd, even or no parity |
Type of polarization: | No impedance for Modbus serial |
Number of addresses: | 0...227 for Modbus serial |
Method of access: | Slave Modbus serial |
Function available: | External bypass controlPre-heatingSmoke extractionMulti-motor cascadeSecond motor setUser managementPorts and services hardeningSecurity event loggingCybersecure firmware updateSingle direction |
Display screen available: | True |
Operating position: | Vertical +/- 10 degree |
Height: | 290.0 mm |
Width: | 190.0 mm |
Depth: | 247.0 mm |
Net weight: | 8.3 kg |
Network frequency: | 50/60 Hz |
Noise level: | 58.0 dB |
Volume of cooling air: | 86.0 m3/h |
Suitable for mounting onto standard rails: | False |
With safety function Safely Limited Speed (SLS): | False |
With safety function Safe Direction (SDI): | False |
With safety function Safely Limited Position (SLP): | False |
With safety function Safe brake management (SBC/SBT): | False |
With safety function Safe Operating Stop (SOS): | False |
With safety function Safe Position (SP): | False |
With safety function Safe programmable logic: | False |
With safety function Safe Speed Monitor (SSM): | False |
With safety function Safe Stop 1 (SS1): | False |
With sft fct Safe Stop 2 (SS2): | False |
With safety function Safe torque off (STO): | False |
In short
Reference ATS480D88Y
Product Name soft starter, Altistart 480, 790A, 208 to 690V AC, control supply 110 to 230V AC - ATS480D88Y
Related Categories