SCHNEIDER
variable speed drive ATV212 - 0.75kW - 1hp - 480V - 3ph - EMC - IP21 - ATV212H075N4
ATV212H075N4
€405.35 Excl. Tax
€486.42 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Device short name: | ATV212 |
---|---|
Product destination: | Asynchronous motors |
Network number of phases: | 3 phases |
Motor power kW: | 0.75 kW |
Motor power hp: | 1 hp |
Supply voltage limits: | 323...528 V |
Supply frequency: | 50...60 Hz - 5...5 % |
Line current: | 1.4 A at 480 V1.7 A at 380 V |
Range of product: | Altivar 212 |
Product or component type: | Variable speed drive |
Product specific application: | Pumps and fans in HVAC |
Communication port protocol: | ModbusMETASYS N2APOGEE FLNLonWorksBACnet |
[Us] rated supply voltage: | 380...480 V - 15...10 % |
EMC filter: | Class C2 EMC filter integrated |
IP degree of protection: | IP21 |
Apparent power: | 1.6 kVA at 380 V |
---|---|
Continuous output current: | 2.2 A at 380 V2.2 A at 460 V |
Maximum transient current: | 2.4 A for 60 s |
Speed drive output frequency: | 0.5...200 Hz |
Speed range: | 1...10 |
Speed accuracy: | +/- 10 % of nominal slip 0.2 Tn to Tn |
Local signalling: | 1 LED (red) for DC bus energized |
Output voltage: | |
Isolation: | Electrical between power and control |
Type of cable: | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPRWithout mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVCWith UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
Electrical connection: | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10 |
Tightening torque: | 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T)0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
Supply: | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply: 24 V DC (21...27 V), |
Sampling duration: | 2 ms +/- 0.5 ms F discrete2 ms +/- 0.5 ms R discrete2 ms +/- 0.5 ms RES discrete3.5 ms +/- 0.5 ms VIA analog22 ms +/- 0.5 ms VIB analog |
Response time: | FM 2 ms, tolerance +/- 0.5 ms for analog output(s)FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
Accuracy: | +/- 0.6 % (VIA) for a temperature variation 60 °C+/- 0.6 % (VIB) for a temperature variation 60 °C+/- 1 % (FM) for a temperature variation 60 °C |
Linearity error: | VIA: +/- 0.15 % of maximum value for inputVIB: +/- 0.15 % of maximum value for inputFM: +/- 0.2 % for output |
Analogue output type: | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bitsFM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
Discrete output type: | Configurable relay logic: (FLA, FLC) NO - 100000 cyclesConfigurable relay logic: (FLB, FLC) NC - 100000 cyclesConfigurable relay logic: (RY, RC) NO - 100000 cycles |
Minimum switching current: | 3 mA at 24 V DC for configurable relay logic |
Maximum switching current: | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
Discrete input type: | F programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmR programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmRES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
Discrete input logic: | Positive logic (source) (F, R, RES), = 11 V (state 1)Negative logic (sink) (F, R, RES), >= 16 V (state 0), |
Dielectric strength: | 3535 V DC between earth and power terminals5092 V DC between control and power terminals |
Insulation resistance: | >= 1 mOhm 500 V DC for 1 minute |
Frequency resolution: | Display unit: 0.1 HzAnalog input: 0.024/50 Hz |
Communication service: | Read device identification (43)Time out setting from 0.1 to 100 sWrite single register (06)Write multiple registers (16) 2 words maximumMonitoring inhibitableRead holding registers (03) 2 words maximum |
Option card: | Communication card for LonWorks |
Power dissipation in W: | 55 W |
Air flow: | 19 m3/h |
Functionality: | Mid |
Specific application: | HVAC |
Discrete and process manufacturing: | Compressor for scroll Building - HVACFan Building - HVACPump Building - HVAC |
Power range: | 0.55...1 kW at 380...440 V 3 phases0.55...1 kW at 480...500 V 3 phases |
Motor starter type: | Variable speed drive |
Discrete output number: | 2 |
Analogue input number: | 2 |
Analogue input type: | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable PTC probe: 0...6 probes, impedance: 1500 OhmVIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
Analogue output number: | 1 |
Physical interface: | 2-wire RS 485 |
Connector type: | 1 open style1 RJ45 |
Transmission rate: | 9600 bps or 19200 bps |
Transmission frame: | RTU |
Number of addresses: | 1...247 |
Data format: | 8 bits, 1 stop, odd even or no configurable parity |
Type of polarization: | No impedance |
Asynchronous motor control profile: | Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)Voltage/frequency ratio - Energy Saving, quadratic U/fVoltage/frequency ratio, 2 pointsFlux vector control without sensor, standardVoltage/frequency ratio, 5 points |
Torque accuracy: | +/- 15 % |
Transient overtorque: | 120 % of nominal motor torque +/- 10 % for 60 s |
Acceleration and deceleration ramps: | Automatic based on the loadLinear adjustable separately from 0.01 to 3200 s |
Motor slip compensation: | Not available in voltage/frequency ratio motor controlAutomatic whatever the loadAdjustable |
Switching frequency: | 6...16 kHz adjustable12...16 kHz with derating factor |
Nominal switching frequency: | 12 kHz |
Braking to standstill: | By DC injection |
Network frequency: | 47.5...63 Hz |
Prospective line Isc: | 5 kA |
Protection type: | Overheating protection: driveThermal power stage: driveShort-circuit between motor phases: driveInput phase breaks: driveOvercurrent between output phases and earth: driveOvervoltages on the DC bus: driveBreak on the control circuit: driveAgainst exceeding limit speed: driveLine supply overvoltage and undervoltage: driveLine supply undervoltage: driveAgainst input phase loss: driveThermal protection: motorMotor phase break: motorWith PTC probes: motor |
Width: | 107 mm |
Height: | 143 mm |
Depth: | 150 mm |
Product weight: | 2 kg |
In short
Reference ATV212H075N4
Product Name variable speed drive ATV212 - 0.75kW - 1hp - 480V - 3ph - EMC - IP21 - ATV212H075N4
Range Altivar 212
Related Categories