SCHNEIDER
variable speed drive - 22kW- 400V - 3 phases - ATV340 - ATV340D22N4
ATV340D22N4
€2,721.75 Excl. Tax
€3,266.10 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Altivar Machine ATV340 |
---|---|
Product or component type: | Variable speed drive |
Product specific application: | Machine |
Variant: | Standard version |
Design of frequency changer: | U converter |
Mounting mode: | Cabinet mount |
Communication port protocol: | Modbus serial |
Option card: | Communication module, Profibus DP V1Communication module, PROFINETCommunication module, DeviceNetCommunication module, CANopenCommunication module, EtherCAT |
Network number of phases: | 3 phases |
Supply frequency: | 50...60 Hz +/- 5 % |
[Us] rated supply voltage: | 380...480 V - 15...10 % |
[Us] rated supply voltage: | 380...480 V |
Relative symmetric mains voltage tolerance: | 10 % |
Relative symmetric network frequency tolerance: | 5 % |
Nominal output current: | 46.0 A |
Number of input phases: | 3 |
Number of output phases: | 3 |
Motor power kW: | 30 kW for normal duty22 kW for heavy duty |
Motor power hp: | 40 hp for normal duty30 hp for heavy duty |
EMC filter: | Class C3 EMC filter integrated |
IP degree of protection: | IP20 |
Discrete input number: | 5 |
---|---|
Discrete input type: | PTI programmable as pulse input: 0...30 kHz, 24 V DC (30 V)DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm programmable |
Discrete input logic: | 16 preset speeds |
Discrete output number: | 2.0 |
Discrete output type: | Programmable output DQ1, DQ2 30 V DC 100 mA |
Analogue input number: | 2 |
Analogue input type: | AI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI1 software-configurable temperature probe or water level sensorAI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bitsAI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
Analogue output number: | 2 |
Analogue output type: | Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSoftware-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits |
Relay output number: | 2 |
Relay output type: | Relay outputs R1ARelay outputs R1C electrical durability 100000 cyclesRelay outputs R2ARelay outputs R2C electrical durability 100000 cycles |
Output voltage: | |
Number of inputs, bidirectional, not potential-free: | 0 |
Number of inputs, potential-free: | 0 |
Maximum switching current: | Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1C on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCRelay output R2C on resistive load, cos phi = 1: 5 A at 250 V ACRelay output R2C on resistive load, cos phi = 1: 5 A at 30 V DCRelay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Minimum switching current: | Relay output R1B: 5 mA at 24 V DCRelay output R2C: 5 mA at 24 V DC |
Encoder protocol: | 1 VppEnDat 2.2ResolverRS 422SSI 24VSSI 5VTTL/HTL |
Computer port: | True |
Optical interface present: | False |
Physical interface: | 2-wire RS 485 |
Connector type: | 1 RJ45 |
Method of access: | Slave Modbus RTU |
Transmission rate: | 4.8 kbit/s9.6 kbit/s19.2 kbit/s38.4 kbit/s |
Transmission frame: | RTU |
Number of addresses: | 1...247 |
Data format: | 8 bits, configurable odd, even or no parity |
Type of polarization: | No impedance |
Number of HW interfaces parallel: | 0 |
Number of HW interfaces industrial Ethernet: | 0 |
Number of HW interfaces PROFINET: | 0 |
Number of HW interfaces serial RS232: | 0 |
Number of HW interfaces serial RS422: | 0 |
Number of HW interfaces serial RS485: | 1 |
Number of HW interfaces serial TTY: | 0 |
Number of HW interfaces USB: | 0 |
Number of HW interfaces other: | 0 |
Supporting protocol for AS-Interface Safety at Work: | False |
Supporting protocol for ASI: | False |
Supporting protocol for SUCONET: | False |
Supporting protocol for BACnet: | False |
Supporting protocol for CAN: | True |
Supporting protocol for Data-Highway: | False |
Supporting protocol for DeviceNet: | False |
Supporting protocol for DeviceNet Safety: | False |
Supporting protocol for EtherNet/IP: | False |
Supporting protocol for Foundation Fieldbus: | False |
Supporting protocol for INTERBUS: | False |
Supporting protocol for INTERBUS-Safety: | False |
Supporting protocol for KNX: | False |
Supporting protocol for LON: | False |
Supporting protocol for MODBUS: | True |
Supporting protocol for other bus systems: | True |
Supporting protocol for PROFIBUS: | True |
Supporting protocol for PROFINET CBA: | True |
Supporting protocol for PROFINET IO: | True |
Supporting protocol for PROFIsafe: | False |
Supporting protocol for SafetyBUS P: | False |
Supporting protocol for SERCOS: | False |
Supporting protocol for TCP/IP: | False |
4 quadrant operation possible: | True |
Asynchronous motor control profile: | Variable torque standardConstant torque standardOptimized torque mode |
Pollution degree: | 2 conforming to EN/IEC 61800-5-1 |
Synchronous motor control profile: | Permanent magnet motorReluctance motor |
Maximum output frequency: | 0.599 kHz |
Acceleration and deceleration ramps: | Linear adjustable separately from 0.01...9999 sS, U or customized |
Motor slip compensation: | AdjustableCan be suppressedAutomatic whatever the loadNot available in permanent magnet motor law |
Switching frequency: | 2...16 kHz adjustable6...16 kHz with derating factor |
Nominal switching frequency: | 4 kHz |
Speed drive output frequency: | 0.1...599 Hz |
Braking to standstill: | By DC injection |
Brake chopper integrated: | True |
Line current: | 60.1 A at 380 V (normal duty)48.6 A at 480 V (normal duty)63.5 A at 380 V (heavy duty)50.6 A at 480 V (heavy duty)64.1 A at 480 V with external line choke (heavy duty)50.8 A at 380 V with external line choke (normal duty) |
Maximum associated fuse rating: | 100.0 A |
Maximum input current: | 63.5 A |
Maximum output voltage: | 480 V |
Nominal output power: | 22.0 kW |
Apparent power: | 45.1 kVA at 480 V (normal duty)42.1 kVA at 480 V (heavy duty) |
Maximum transient current: | 68.2 A during 60 s (normal duty)69 A during 60 s (heavy duty)83.7 A during 2 s (normal duty)83 A during 2 s (heavy duty) |
Electrical connection: | Screw terminal, clamping capacity: 0.2...2.5 mm² for controlScrew terminal, clamping capacity: 6...25 mm² for motorScrew terminal, clamping capacity: 10...25 mm² for line sideScrew terminal, clamping capacity: 10...25 mm² for DC bus |
Capacity of DC link: | 2250.0 µF |
Network frequency: | 50...60 Hz |
Prospective line Isc: | 22 kA |
1 phase low current possible: | False |
Base load current at high overload: | 46.0 A |
Base load current at low overload: | 62.0 A |
Application in domestic and commercial area permitted: | False |
Application in industrial area permitted: | True |
EMC limit value (complied): | True |
Power loss per device current dependent: | 746.0 W |
Power loss static current independent: | 19.0 W |
Power dissipation in W: | Natural convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty)Forced convection: 486 W at 380 V, switching frequency 4 kHz (heavy duty)Natural convection: 39 W at 380 V, switching frequency 4 kHz (normal duty)Forced convection: 631 W at 380 V, switching frequency 4 kHz (normal duty) |
Housing material: | Plastic |
With safety function Safely Limited Speed (SLS): | True |
With safety function Safe brake management (SBC/SBT): | True |
With safety function Safe Operating Stop (SOS): | False |
With safety function Safe Position (SP): | False |
With safety function Safe programmable logic: | False |
With safety function Safe Speed Monitor (SSM): | False |
With safety function Safe Stop 1 (SS1): | True |
With sft fct Safe Stop 2 (SS2): | False |
With safety function Safe torque off (STO): | True |
With safety function Safely Limited Position (SLP): | False |
With safety function Safe Direction (SDI): | False |
Protection type: | Thermal protection: motorSafe torque off: motorMotor phase loss: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent: driveOutput overcurrent between motor phase and earth: driveOutput overcurrent between motor phases: driveShort-circuit between motor phase and earth: driveShort-circuit between motor phases: driveMotor phase loss: driveDC Bus overvoltage: driveLine supply overvoltage: driveLine supply undervoltage: driveInput supply loss: driveExceeding limit speed: driveBreak on the control circuit: drive |
Operating element present: | True |
Width: | 180.0 mm |
Height: | 385.0 mm |
Depth: | 249.0 mm |
Net weight: | 10.2 kg |
Specific application: | Machine |
Motor starter type: | Variable speed drive |
Accuracy: | +/- 0.6 % AI1, AI2 for a temperature variation 60 °C analog input+/- 1 % AQ1 for a temperature variation 60 °C analog output |
Connector type: | connector(s)1 x RJ45, Modbus serial on front face connector(s)1 x RJ45, Modbus serial for HMI on front face |
Discrete input logic: | Positive logic (source) (DI1...DI5), 11 V (state 1)Negative logic (sink) (DI1...DI5), > 16 V (state 0), Positive logic (source) (PTI), 2.5 V (state 1)Positive logic (source) (STOA, STOB), 11 V (state 1) |
Input compatibility: | DI1...DI5: discrete input level 1 PLC conforming to EN/IEC 61131-2PTI: pulse input level 1 PLC conforming to IEC 65A-68STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Input/output type: | Programmable as logic input/output DQ1: 0...1 kHz, Programmable as logic input/output DQ2: 0...1 kHz, |
Continuous output current: | 62 A at 4 kHz for normal duty46 A at 4 kHz for heavy duty |
Sampling duration: | 2 ms +/- 0.5 ms (DI1...DI5) - discrete input5 ms +/- 1 ms (PTI) - pulse input1 ms +/- 1 ms (AI1, AI2) - analog input5 ms +/- 1 ms (AQ1) - analog output2 ms +/- 0.5 ms (DQ1, DQ2) - discrete input/output |
Refresh time: | Relay output (R1, R2): 5 ms (+/- 0.5 ms) |
Safety function: | STO (safe torque off) SIL 3 |
Vibration resistance: | 1.5 mm peak to peak (f= 2...19 Hz) conforming to EN/IEC 60721-3-3 class 3M31 gn (f= 9...200 Hz) conforming to EN/IEC 60721-3-3 class 3M3 |
Discrete and process manufacturing: | Hoisting tower craneHoisting other applicationMaterial handling grouping conveyorMaterial handling palletizer - high performanceMaterial working (wood, ceramic, stone, pvc, metal) cutting - high accuracyMaterial working (wood, ceramic, stone, pvc, metal) polishingMaterial working (wood, ceramic, stone, pvc, metal) grindingMaterial working (wood, ceramic, stone, pvc, metal) slitterPackaging filling bottles - synchronized operationPackaging feed conveyor - medium performancePackaging grouping boxingPackaging conveyorPackaging elevatorPackaging other applicationHoisting standard crane - hoistMaterial handling automatic storage / retrieval systemPackaging shrinking wrapping |
In short
Reference ATV340D22N4
Product Name variable speed drive - 22kW- 400V - 3 phases - ATV340 - ATV340D22N4
Related Categories