SCHNEIDER
variable speed drive ATV630 - 1.5kW/2HP - 380...480V - IP21/UL type 1 - ATV630U15N4
ATV630U15N4
€859.13 Excl. Tax
€1,030.96 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Altivar Process ATV600 |
---|---|
Product or component type: | Variable speed drive |
Product specific application: | Process and utilities |
Device short name: | ATV630 |
Variant: | Standard version |
Product destination: | Asynchronous motorsSynchronous motors |
EMC filter: | Integrated with 50 m conforming to EN/IEC 61800-3 category C2Integrated with 150 m conforming to EN/IEC 61800-3 category C3 |
IP degree of protection: | IP21 conforming to IEC 61800-5-1IP21 conforming to IEC 60529 |
[Us] rated supply voltage: | 380...480 V |
Degree of protection: | UL type 1 conforming to UL 508C |
Type of cooling: | Forced convection |
Supply frequency: | 50...60 Hz - 5...5 % |
[Us] rated supply voltage: | 380...480 V - 15...10 % |
Motor power kW: | 1.5 kW (normal duty)0.75 kW (heavy duty) |
Motor power hp: | 2 hp normal duty1 hp heavy duty |
Line current: | 3 A at 380 V (normal duty)2.6 A at 480 V (normal duty)1.7 A at 380 V (heavy duty)1.5 A at 480 V (heavy duty) |
Prospective line Isc: | 50 kA |
Apparent power: | 2.2 kVA at 480 V (normal duty)1.2 kVA at 480 V (heavy duty) |
Continuous output current: | 4 A at 4 kHz for normal duty2.2 A at 4 kHz for heavy duty |
Maximum transient current: | 4.4 A during 60 s (normal duty)3.3 A during 60 s (heavy duty) |
Asynchronous motor control profile: | Variable torque standardConstant torque standardOptimized torque mode |
Synchronous motor control profile: | Permanent magnet motorSynchronous reluctance motor |
Speed drive output frequency: | 0.1...500 Hz |
Nominal switching frequency: | 4 kHz |
Switching frequency: | 2...12 kHz adjustable4...12 kHz with derating factor |
Safety function: | STO (safe torque off) SIL 3 |
Discrete input logic: | 16 preset speeds |
Communication port protocol: | Modbus TCPEthernetModbus serial |
Option card: | Slot A: communication module, Profibus DP V1Slot A: communication module, ProfinetSlot A: communication module, DeviceNetSlot A: communication module, Modbus TCP/EtherNet/IPSlot A: communication module, CANopen daisy chain RJ45Slot A: communication module, CANopen SUB-D 9Slot A: communication module, CANopen screw terminalsSlot A/slot B: digital and analog I/O extension moduleSlot A/slot B: output relay extension moduleSlot A: communication module, Ethernet IP/Modbus TCP/MD-LinkCommunication module, BACnet MS/TPCommunication module, Ethernet Powerlink |
Design of frequency changer: | U converter |
---|---|
Network frequency: | 50...60 Hz |
Ambient air transport temperature: | -40...70 °C |
Relative symmetric mains voltage tolerance: | 10 % |
Maximum output voltage: | 480.0 V |
Relative symmetric network frequency tolerance: | 5 % |
Maximum acceleration under shock impact (during operation): | 150 m/s² at 11 ms |
Permitted relative humidity (during operation): | Class 3K5 according to EN 60721-3 |
Maximum acceleration under vibrational stress (during operation): | 10 m/s² at 13...200 Hz |
Nominal output power: | 1.5 W |
4 quadrant operation possible: | False |
Permitted relative humidity (during transport): | Class 2K5 according to EN 60721-3 |
Permitted relative humidity (during storage): | Class 1K5 according to EN 60721-3 |
Capacity of DC link: | 235.0 µF |
Maximum deflection under vibratory load (during operation): | 1.5 mm at 2...13 Hz |
Operating element present: | True |
Number of HW interfaces serial TTY: | 0 |
Power loss per device current dependent: | 74.0 W |
Power loss static current independent: | 14.0 W |
Number of output phases: | 3 |
Maximum acceleration under vibratory load (during transport): | 10 m/s² at 13...200 Hz |
Number of input phases: | 3 |
Number of inputs, potential-free: | 0 |
Maximum deflection under vibratory load (during transport): | 1.5 mm at 2...13 Hz |
Brake chopper integrated: | False |
Maximum acceleration under shock load (during transport): | 150 m/s² at 11 ms |
Number of HW interfaces USB: | 0 |
Number of HW interfaces other: | 0 |
Optical interface present: | False |
Computer port: | True |
Supporting protocol for TCP/IP: | True |
Application in industrial area permitted: | True |
Application in domestic and commercial area permitted: | False |
Supporting protocol for PROFIBUS: | True |
Number of HW interfaces industrial Ethernet: | 1 |
Number of inputs, bidirectional, not potential-free: | 0 |
1 phase low current possible: | False |
Number of HW interfaces parallel: | 0 |
Supporting protocol for KNX: | False |
Supporting protocol for ASI: | False |
Number of HW interfaces PROFINET: | 0 |
Supporting protocol for CAN: | True |
Supporting protocol for INTERBUS: | False |
Supporting protocol for DeviceNet: | False |
Supporting protocol for SUCONET: | False |
Supporting protocol for LON: | False |
Supporting protocol for MODBUS: | True |
Supporting protocol for Data-Highway: | False |
Supporting protocol for PROFINET IO: | True |
Supporting protocol for PROFINET CBA: | True |
Maximum acceleration under shock load (during storage): | 150 m/s² at 11 ms |
Supporting protocol for Foundation Fieldbus: | False |
Supporting protocol for SERCOS: | False |
Maximum deflection under vibratory load (during storage): | 1.5 mm at 2...13 Hz |
Supporting protocol for DeviceNet Safety: | False |
Supporting protocol for INTERBUS-Safety: | False |
Supporting protocol for PROFIsafe: | False |
Supporting protocol for EtherNet/IP: | True |
Supporting protocol for AS-Interface Safety at Work: | False |
Maximum acceleration under vibratory load (during storage): | 10 m/s² at 13...200 Hz |
With safety function Safe torque off (STO): | True |
With sft fct Safe Stop 2 (SS2): | False |
With safety function Safe Stop 1 (SS1): | False |
Supporting protocol for SafetyBUS P: | False |
Supporting protocol for BACnet: | False |
Supporting protocol for other bus systems: | False |
Nominal output current: | 4.0 A |
With safety function Safe brake management (SBC/SBT): | False |
With safety function Safe Operating Stop (SOS): | False |
With safety function Safely Limited Position (SLP): | False |
With safety function Safely Limited Speed (SLS): | False |
With safety function Safe Speed Monitor (SSM): | False |
With safety function Safe Direction (SDI): | False |
Base load current at high overload: | 2.2 A |
Base load current at low overload: | 4.0 A |
Number of HW interfaces serial RS232: | 0 |
With safety function Safe programmable logic: | False |
With safety function Safe Position (SP): | False |
EMC limit value (complied): | True |
Environmental class (during transport): | Class 2C3 according to EN 60721-3-2Class 2S1 according to EN 60721-3-2 |
Environmental class (during operation): | Class 3C3 according to IEC 60721-3-3Class 3S3 according to IEC 60721-3-3 |
Environmental class (during storage): | Class 1C3 according to EN 60721-3-1Class 1S2 according to EN 60721-3-1 |
Number of HW interfaces serial RS422: | 0 |
Number of HW interfaces serial RS485: | 1 |
Mounting mode: | Wall mount |
Network number of phases: | 3 phases |
Discrete output number: | 0 |
Discrete output type: | Relay outputs R1A, R1B, R1C 250 V AC 3000 mARelay outputs R1A, R1B, R1C 30 V DC 3000 mARelay outputs R2A, R2C 250 V AC 5000 mARelay outputs R2A, R2C 30 V DC 5000 mARelay outputs R3A, R3C 250 V AC 5000 mARelay outputs R3A, R3C 30 V DC 5000 mA |
Output voltage: | |
Permissible temporary current boost: | 1.1 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty) |
Motor slip compensation: | Can be suppressedAdjustableNot available in permanent magnet motor lawAutomatic whatever the load |
Acceleration and deceleration ramps: | Linear adjustable separately from 0.01...9999 s |
Physical interface: | Ethernet2-wire RS 485 |
Braking to standstill: | By DC injection |
Protection type: | Thermal protection: motorSafe torque off: motorMotor phase break: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
Transmission rate: | 10, 100 Mbits4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
Frequency resolution: | Display unit: 0.1 HzAnalog input: 0.012/50 Hz |
Transmission frame: | RTU |
Electrical connection: | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10 |
Connector type: | RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial |
Data format: | 8 bits, configurable odd, even or no parity |
Type of polarization: | No impedance |
Exchange mode: | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
Number of addresses: | 1...247 for Modbus serial |
Method of access: | Slave Modbus TCP |
Supply: | External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), |
Local signalling: | 3 LEDs for local diagnostic3 LEDs (dual colour) for embedded communication status4 LEDs (dual colour) for communication module status1 LED (red) for presence of voltage |
Width: | 144 mm |
Height: | 350 mm |
Depth: | 203 mm |
Product weight: | 4.5 kg |
Analogue input number: | 3 |
Analogue input type: | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
Discrete input number: | 8 |
Discrete input type: | DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC ( |
Input compatibility: | DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Discrete input logic: | Positive logic (source) (DI1...DI8), 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0), |
Analogue output number: | 2 |
Analogue output type: | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSoftware-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable current DQ-, DQ+: 30 V DCSoftware-configurable current DQ-, DQ+: 100 mA |
Sampling duration: | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input5 ms +/- 1 ms (DI5, DI6) - discrete input5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input10 ms +/- 1 ms (AO1) - analog output |
Accuracy: | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
Linearity error: | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAO1, AO2: +/- 0.2 % for analog output |
Relay output number: | 3 |
Relay output type: | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
Refresh time: | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Minimum switching current: | Relay output R1, R2, R3: 5 mA at 24 V DC |
Maximum switching current: | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Isolation: | Between power and control terminals |
Maximum output frequency: | 500 kHz |
Maximum associated fuse rating: | 8.0 A |
Maximum input current: | 3.0 A |
Specific application: | Utility |
IP degree of protection: | IP21 |
Discrete and process manufacturing: | Compressor centrifugal Building - HVACOther application Food and beverage processingFan Mining mineral and metalPump Mining mineral and metalFan Oil and gasOther application Water and waste waterScrew compressor Building - HVACPump Food and beverage processingFan Food and beverage processingAtomization Food and beverage processingElectro submersible pump (ESP) Oil and gasWater injection pump Oil and gasJet fuel pump Oil and gasCompressor for refinery Oil and gasCentrifuge pump Water and waste waterPositive displacement pump Water and waste waterElectro submersible pump (ESP) Water and waste waterScrew pump Water and waste waterLobe compressor Water and waste waterScrew compressor Water and waste waterCompressor centrifugal Water and waste waterFan Water and waste waterConveyor Water and waste waterMixer Water and waste water |
Power range: | 1.1...2 kW at 380...440 V 3 phases1.1...2 kW at 480...500 V 3 phases |
Motor starter type: | Variable speed drive |
Housing material: | Plastic |
Quantity per set: | 1 |
Enclosure mounting: | Wall mounted |
In short
Reference ATV630U15N4
Product Name variable speed drive ATV630 - 1.5kW/2HP - 380...480V - IP21/UL type 1 - ATV630U15N4
Related Categories