SCHNEIDER
analog input module X80 - 4 inputs - temperature - BMXART0414
BMXART0414
€469.82 Excl. Tax
€563.78 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Modicon X80 |
---|---|
Product or component type: | Analog input module |
Electrical connection: | 40 ways 1 connector |
Input output isolation: | Isolated |
Input level: | Low level |
Analogue input number: | 4 |
Analogue input type: | Voltage +/- 1.28 VVoltage +/- 160 mVVoltage +/- 320 mVVoltage +/- 40 mVVoltage +/- 640 mVVoltage +/- 80 mVResistor 400 Ohm 2 wiresResistor 400 Ohm 3 wiresResistor 400 Ohm 4 wiresResistor 4000 Ohm 2 wiresResistor 4000 Ohm 3 wiresResistor 4000 Ohm 4 wiresTemperature probe -100...+260 °C Cu 10Temperature probe -100...+450 °C Pt 100 conforming to UL/JISTemperature probe -100...+450 °C Pt 1000 conforming to UL/JISTemperature probe -200...+850 °C Pt 100 conforming to IECTemperature probe -200...+850 °C Pt 1000 conforming to IECTemperature probe -60...+180 °C Ni 100Temperature probe -60...+180 °C Ni 1000Thermocouple +130...+1820 °C thermocouple BThermocouple +270...+1300 °C thermocouple NThermocouple -200...+600 °C thermocouple UThermocouple -200...+760 °C thermocouple JThermocouple -200...+900 °C thermocouple LThermocouple -270...+1000 °C thermocouple EThermocouple -270...+1370 °C thermocouple KThermocouple -270...+400 °C thermocouple TThermocouple -50...+1769 °C thermocouple RThermocouple -50...+1769 °C thermocouple S |
Analog/digital conversion: | Sigma delta 16 bits |
---|---|
Analogue input resolution: | 15 bits + sign |
Permitted overload on inputs: | +/- 7.5 V +/- 1.28 V+/- 7.5 V +/- 160 mV+/- 7.5 V +/- 320 mV+/- 7.5 V +/- 40 mV+/- 7.5 V +/- 640 mV+/- 7.5 V +/- 80 mV |
Common mode rejection: | 120 dB 50/60 Hz |
Differential mode rejection: | 60 dB 50/60 Hz |
Cold junction compensation: | External by Pt100 probe |
Type of filter: | First order digital filtering |
Nominal read cycle time: | 400 ms with temperature probe200 ms with thermocouple |
Measurement error: | +/- 0.7 °C Ni 1000 25 °C+/- 1.3 °C Ni 1000 0...60 °C+/- 2 °C Pt 100 0...60 °C+/- 2 °C Pt 1000 0...60 °C+/- 2.1 °C Ni 100 25 °C+/- 2.1 °C Pt 100 25 °C+/- 2.1 °C Pt 1000 25 °C+/- 2.7 °C thermocouple U 25 °C+/- 2.8 °C thermocouple J 25 °C+/- 3 °C Ni 100 0...60 °C+/- 3 °C thermocouple L 25 °C+/- 3.2 °C thermocouple R 25 °C+/- 3.2 °C thermocouple S 25 °C+/- 3.5 °C thermocouple B 25 °C+/- 3.7 °C thermocouple E 25 °C+/- 3.7 °C thermocouple K 25 °C+/- 3.7 °C thermocouple N 25 °C+/- 3.7 °C thermocouple T 25 °C+/- 4 °C Cu 10 0...60 °C+/- 4 °C Cu 10 25 °C+/- 4.5 °C thermocouple J 0...60 °C+/- 4.5 °C thermocouple L 0...60 °C+/- 4.5 °C thermocouple R 0...60 °C+/- 4.5 °C thermocouple S 0...60 °C+/- 4.5 °C thermocouple U 0...60 °C+/- 5 °C thermocouple B 0...60 °C+/- 5 °C thermocouple E 0...60 °C+/- 5 °C thermocouple K 0...60 °C+/- 5 °C thermocouple N 0...60 °C+/- 5 °C thermocouple T 0...60 °C0.05 % of full scale +/- 1.28 V 25 °C0.05 % of full scale +/- 160 mV 25 °C0.05 % of full scale +/- 320 mV 25 °C0.05 % of full scale +/- 40 mV 25 °C0.05 % of full scale +/- 640 mV 25 °C0.05 % of full scale +/- 80 mV 25 °C0.12 % of full scale 400 Ohm 25 °C0.12 % of full scale 4000 Ohm 25 °C |
Temperature drift: | 25 ppm/°C 400 Ohm25 ppm/°C 4000 Ohm25 ppm/°C Ni 100025 ppm/°C thermocouple B25 ppm/°C thermocouple E25 ppm/°C thermocouple J25 ppm/°C thermocouple K25 ppm/°C thermocouple L25 ppm/°C thermocouple N25 ppm/°C thermocouple R25 ppm/°C thermocouple S25 ppm/°C thermocouple T25 ppm/°C thermocouple U30 ppm/°C +/- 1.28 V30 ppm/°C +/- 160 mV30 ppm/°C +/- 320 mV30 ppm/°C +/- 40 mV30 ppm/°C +/- 640 mV30 ppm/°C +/- 80 mV30 ppm/°C Cu 1030 ppm/°C Ni 10030 ppm/°C Pt 10030 ppm/°C Pt 1000 |
Recalibration: | Internal |
Isolation voltage: | 1400 V DC between channels and bus750 V DC between channels750 V DC between channels and ground |
Detection type: | Open circuit Cu 10Open circuit Ni 100Open circuit Ni 1000Open circuit Pt 100Open circuit Pt 1000Open circuit thermocouple BOpen circuit thermocouple EOpen circuit thermocouple JOpen circuit thermocouple KOpen circuit thermocouple LOpen circuit thermocouple NOpen circuit thermocouple ROpen circuit thermocouple SOpen circuit thermocouple TOpen circuit thermocouple U |
Maximum wiring resistance: | 20 Ohm 2 wires Cu 1020 Ohm 2 wires Ni 10020 Ohm 2 wires Pt 10020 Ohm 3 wires Cu 1020 Ohm 3 wires Ni 10020 Ohm 3 wires Pt 100200 Ohm 2 wires Ni 1000200 Ohm 2 wires Pt 1000200 Ohm 3 wires Ni 1000200 Ohm 3 wires Pt 100050 Ohm 4 wires Cu 1050 Ohm 4 wires Ni 10050 Ohm 4 wires Pt 100500 Ohm 4 wires Ni 1000500 Ohm 4 wires Pt 1000 |
Measurement resolution: | 0.1 °C Cu 100.1 °C Ni 1000.1 °C Ni 10000.1 °C Pt 1000.1 °C Pt 10000.1 °C thermocouple B0.1 °C thermocouple E0.1 °C thermocouple J0.1 °C thermocouple K0.1 °C thermocouple L0.1 °C thermocouple N0.1 °C thermocouple R0.1 °C thermocouple S0.1 °C thermocouple T0.1 °C thermocouple U1280/2exp14 mV +/- 1.28 V160/2exp14 mV +/- 160 mV320/2exp14 mV +/- 320 mV40/2exp14 mV +/- 40 mV40/2exp14 mV 400 Ohm4000/2exp14 mV 4000 Ohm640/2exp14 mV +/- 640 mV80/2exp14 mV +/- 80 mV |
Maximum conversion value: | +/- 100 % 400 Ohm+/- 100 % 4000 Ohm+/- 102.5 % +/- 1.28 V+/- 102.5 % +/- 160 mV+/- 102.5 % +/- 320 mV+/- 102.5 % +/- 40 mV+/- 102.5 % +/- 640 mV+/- 102.5 % +/- 80 mV |
Operating altitude: | 0...2000 m2000...5000 m with derating factor |
Status LED: | 1 LED (green)RUN1 LED per channel (green)channel diagnostic1 LED (red)ERR1 LED (red)I/O |
Product weight: | 0.135 kg |
Current consumption: | 150 mA at 3.3 V DC40 mA at 24 V DC |
In short
Reference BMXART0414
Product Name analog input module X80 - 4 inputs - temperature - BMXART0414
Range Modicon X80
Related Categories