SCHNEIDER
discrete module X80 - 8 NO Type A - Isolated relays - 125 V DC/250 V AC - BMXDRA0815
BMXDRA0815
€260.29 Excl. Tax
€312.35 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Modicon X80 |
---|---|
Product or component type: | Relay discrete output module |
Discrete output number: | 8 conforming to EN/IEC 61131-2 |
Discrete output logic: | Positive |
Discrete output voltage: | 24...240 V 19...264 V AC24...125 V 5...150 V DC |
Electrical connection: | 20 ways terminal block |
---|---|
Network frequency: | 50/60 Hz |
Network frequency limits: | 47...63 Hz |
Voltage range: | 5...150 V19...264 V |
[Ith] conventional free air thermal current: | 3 A |
Insulation resistance: | > 10 MOhm 500 V DC |
Power dissipation in W: | 3.6 W |
Response time on output: | |
Typical current consumption: | 40 mA at 3.3 V DC101 mA at 24 V DC |
MTBF reliability: | 3200000 H |
Protection type: | External short-circuit protectionExternal overload protectionExternal overvoltage protection, inductive AC network External overvoltage protection, inductive DC network |
Output overload protection: | Use 1 fast blow fuse per channel or group of channel |
Output overvoltage protection: | Use discharge diode on each output DCUse RC circuit on each output ACUse ZNO surge limiter on each output AC |
Output short-circuit protection: | Use 1 fast blow fuse per channel or group of channel |
Minimum switching current: | 1 mA 5 V DC |
Electrical durability: | AC-12: 200000 cycles at 48 VA 24 V at 0...60 °CAC-12: 300000 cycles at 48 VA 48 V at 0...60 °CAC-12: 150000 cycles at 96 VA 48 V at 0...60 °CAC-12: 300000 cycles at 110 VA 100...120 V at 0...60 °CAC-12: 150000 cycles at 220 VA 100...120 V at 0...60 °CAC-12: 300000 cycles at 220 VA 200...250 V at 0...60 °CAC-12: 150000 cycles at 500 VA 200...250 V at 0...60 °CAC-15: 700000 cycles at 10 VA 24 V at 0...60 °C (load factor 0.4)AC-15: 500000 cycles at 24 VA 24 V at 0...60 °C (load factor 0.4)AC-15: 200000 cycles at 48 VA 24 V at 0...60 °C (load factor 0.4)AC-15: 700000 cycles at 10 VA 48 V at 0...60 °C (load factor 0.4)AC-15: 500000 cycles at 24 VA 48 V at 0...60 °C (load factor 0.4)AC-15: 300000 cycles at 48 VA 48 V at 0...60 °C (load factor 0.4)AC-15: 100000 cycles at 96 VA 48 V at 0...60 °C (load factor 0.4)AC-15: 1000000 cycles at 10 VA 100...120 V at 0...60 °C (load factor 0.4)AC-15: 300000 cycles at 50 VA 100...120 V at 0...60 °C (load factor 0.4)AC-15: 200000 cycles at 110 VA 100...120 V at 0...60 °C (load factor 0.4)AC-15: 70000 cycles at 220 VA 100...120 V at 0...60 °C (load factor 0.4)AC-15: 1000000 cycles at 10 VA 200...250 V at 0...60 °C (load factor 0.4)AC-15: 500000 cycles at 50 VA 200...250 V at 0...60 °C (load factor 0.4)AC-15: 200000 cycles at 110 VA 200...250 V at 0...60 °C (load factor 0.4)AC-15: 150000 cycles at 220 VA 200...250 V at 0...60 °C (load factor 0.4)DC-12: 200000 cycles at 24 W 24 V at 0...60 °CDC-12: 150000 cycles at 48 W 24 V at 0...60 °CDC-12: 150000 cycles at 40 W 48...60 V at 0...60 °CDC-12: 100000 cycles at 45 W 100...125 V at 0...60 °CDC-13: 100000 cycles at 10 W 24 V at 0...60 °CDC-13: 60000 cycles at 24 W 24 V at 0...60 °CDC-13: 40000 cycles at 48 W 24 V at 0...60 °CDC-13: 40000 cycles at 40 W 48...60 V at 0...60 °CDC-13: 100000 cycles at 15 W 100...125 V at 0...60 °C |
Status LED: | 1 LED (green) RUN1 LED per channel (green) channel diagnostic1 LED (red) ERR1 LED (red) I/O |
Net weight: | 0.169 kg |
In short
Reference BMXDRA0815
Product Name discrete module X80 - 8 NO Type A - Isolated relays - 125 V DC/250 V AC - BMXDRA0815
Related Categories