Technical informations
Range: | ComPacT new generation |
---|---|
Range of product: | ComPacT NSX100...250 new generation |
Product or component type: | Trip unit |
Trip unit name: | Micrologic 7.2 E |
Trip unit technology: | Electronic |
Range compatibility: | ComPacT new generation NSX160ComPacT new generation NSX100ComPacT new generation NSX250 |
Device application: | Distribution |
Poles description: | 4P |
Protected poles description: | 3D + N/24D3D + OSN3D |
Neutral position: | Left |
Trip unit protection functions: | LSIR |
Protection type: | L |
[In] rated current: | 40 A at 40 °C |
[Ue] rated operational voltage: | 440 V AC 50/60 Hz |
Network type: | AC |
Network frequency: | 50/60 Hz |
Mounting mode: | Fixed |
Long time pick-up adjustment type Ir: | Adjustable 9 settings |
---|---|
Long time pick-up adjustment range: | 18...40 A |
Long time delay adjustment type: | Adjustable |
[tr] long-time delay adjustment range: | 15...400 s at 1.5 x Ir0.35...11 s at 7.2 x Ir0.5...16 s at 6 x Ir |
Neutral protection setting: | 0.5 x Ir (3D + N/2)1 x Ir (4D)1.6 x Ir (3D + OSN)No protection (3D) |
Thermal memory: | 20 minutes before and after tripping |
Short-time pick-up adjustment type Isd: | Adjustable |
[Isd] short-time pick-up adjustment range: | 1.5...10 x Ir |
Short-time delay adjustment type: | Adjustable |
[tsd] short-time delay adjustment range: | 0...0.4 s |
Instantaneous pick-up adjustment type Ii: | Adjustable |
Instantaneous pick-up adjustment range: | 1.5...15 x In |
Earth-leakage protection: | Integrated |
Earth-leakage protection class: | Class A |
Residual earth-leakage sensitity adjustment type: | Adjustable |
[I?n] residual earth-leakage sensitive adjustment: | 0.03 A0.1 A0.3 A0.5 A1 A3 A5 A |
Operating mode: | OFF using the I?n rotary switch |
Residual earth-leakage time delay adjustment type: | Adjustable |
[?t] residual earth-leakage time delay adjustment: | 0 ms60 ms150 ms500 ms1 s |
Zone selective interlocking ZSI: | Without |
Local signalling: | Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload |
Display type: | LCD display |
Type of measurement: | Energy meter |
Communication of data: | Maintenance indicatorsInstantaneous and demand valuesTime-stamped histories and event tablesMaximeters/minimetersEarth leakage currentDemand current and powerPower qualityTest reportsProtection and alarm settingsEnergy metering |