SCHNEIDER
Circuit breaker, ComPacT NSXm 100F, 36kA/415VAC, 4 poles 4D (neutral fully protected), TMD trip unit 40A, lugs/busbars - C11F4TM040B
C11F4TM040B
€288.84 Excl. Tax
€346.61 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | ComPacT new generation |
---|---|
Product name: | ComPacT NSXm new generation |
Range of product: | ComPacT NSXm new generation |
Device short name: | NSXm 100F |
Product or component type: | Circuit breaker |
Device application: | Distribution |
Poles description: | 4P |
Protected poles description: | 4D |
Neutral position: | Left |
[In] rated current: | 40 A at 40 °C |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz |
Network type: | AC |
Network frequency: | 50/60 Hz |
Suitability for isolation: | Yes conforming to IEC 60947-2 |
Utilisation category: | Category A |
Breaking capacity: | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking capacity code: | F 36 kA 415 V AC |
Trip unit name: | TM-D |
Trip unit technology: | Thermal-magnetic |
Trip unit protection functions: | LI |
Control type: | Toggle |
Mounting mode: | Fixed |
[Ui] rated insulation voltage: | 800 V AC 50/60 Hz |
---|---|
[Uimp] rated impulse withstand voltage: | 8 kV |
[Ics] rated service breaking capacity: | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-230 kA at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA at 500 V AC 50/60 Hz conforming to IEC 60947-210 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
Mechanical durability: | 20000 cycles |
Electrical durability: | 20000 cycles at 440 V In/210000 cycles at 440 V In10000 cycles at 690 V In/25000 cycles at 690 V In |
Power dissipation per pole: | 3.46 W |
Mounting support: | Backplate |
Mounting position: | Horizontal and verticalFlat on the back |
Upside connection: | Front |
Downside connection: | Front |
Connections - terminals: | compression lug/busbar |
Connection pitch: | 35 mm with spreaders27 mm without spreaders |
9 mm pitches: | 12 module |
Trip unit rating: | 40 A at 40 °C |
Long time pick-up adjustment type Ir: | Adjustable |
Long time pick-up adjustment range: | 0.7...1 x In |
Long time delay adjustment type: | Fixed |
Neutral protection setting: | 1 x Ir (4D) |
Instantaneous pick-up adjustment type Ii: | Fixed |
Instantaneous pick-up adjustment range: | 600 A |
Earth-leakage protection: | Without |
Number of slots: | 1 slot(s) for auxiliary switch OF1 slot(s) for alarm switch SD1 slot(s) for voltage release MN or MX |
Local signalling: | Flag (green) for presence of auxiliary contacts |
Width: | 108 mm |
Height: | 137 mm |
Depth: | 80 mm |
Net weight: | 1.42 kg |
Colour: | Grey (RAL 7016) |
In short
Reference C11F4TM040B
Product Name Circuit breaker, ComPacT NSXm 100F, 36kA/415VAC, 4 poles 4D (neutral fully protected), TMD trip unit 40A, lugs/busbars - C11F4TM040B
Range ComPacT nouvelle génération
Related Categories