SCHNEIDER
Circuit breaker, ComPacT NS1250N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 5.0E control unit, 1250A - C125N45EFM
C125N45EFM
€3,998.70 Excl. Tax
€4,798.44 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | ComPacT |
---|---|
Product name: | ComPacT NS new generation |
Range of product: | ComPacT NS630b...1600 new generation |
Product or component type: | Circuit breaker |
Device application: | Distribution |
Poles description: | 4P |
Protected poles description: | 4D |
Neutral position: | Left |
[In] rated current: | 1250 A at 50 °C |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz |
Network type: | AC |
Network frequency: | 50/60 Hz |
Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
Utilisation category: | Category B |
Breaking capacity: | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-240 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking capacity code: | N 50 kA 415 V AC |
Trip unit name: | MicroLogic 5.0 E |
Trip unit technology: | Electronic |
Trip unit protection functions: | LSI |
Control type: | Manually operated |
Mounting mode: | Fixed |
[Ui] rated insulation voltage: | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
---|---|
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947-2 |
[Ics] rated service breaking capacity: | 50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-240 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Icw] rated short-time withstand current: | 19.2 kA 1 s conforming to IEC 60947-2 |
Mechanical durability: | 10000 cycles |
Electrical durability: | 2000 cycles at 690 V In3000 cycles at 690 V In/24000 cycles at 440 V In5000 cycles at 440 V In/2 |
Power losses: | 44 W |
Mounting support: | Backplate |
Upside connection: | Front |
Downside connection: | Front |
Connection pitch: | 70 mm |
Protection type: | L |
Trip unit rating: | 1250 A at 50 °C |
Long time pick-up adjustment type Ir: | Adjustable 9 settings |
Long time pick-up adjustment range: | 0.4...1 x In |
Long time delay adjustment type: | Adjustable 9 settings |
[tr] long-time delay adjustment range: | 12.5...600 s at 1.5 x Ir0.5...24 s at 6 x Ir0.7...16.6 s at 7.2 x Ir |
Thermal memory: | 20 mn |
Short-time pick-up adjustment type Isd: | Adjustable 9 settings |
[Isd] short-time pick-up adjustment range: | 1.5...10 x Ir |
Short-time delay adjustment type: | Adjustable |
[tsd] short-time delay adjustment range: | 0.1...0.4 s I²t=on0...0.4 s I²t=off |
Instantaneous pick-up adjustment type Ii: | Adjustable |
Instantaneous pick-up adjustment range: | Off2...15 x In |
Earth-leakage protection: | Without |
Neutral protection setting: | No protection (3D)0.5 x Ir (3D + N/2)1 x Ir (4D) |
Zone selective interlocking ZSI: | With |
Auxiliary contact composition: | 1 NO/NC |
Local signalling: | 4 LEDs (red) for fault indication1 LED (yellow) for overload |
Display type: | LCD display |
Type of measurement: | Energy meter |
Width: | 280 mm |
Height: | 327 mm |
Depth: | 147 mm |
Net weight: | 18 kg |
Compatibility code: | NS1250 |
In short
Reference C125N45EFM
Product Name Circuit breaker, ComPacT NS1250N, 50kA at 415VAC, 4P, fixed, manually operated, MicroLogic 5.0E control unit, 1250A - C125N45EFM
Range
Related Categories