SCHNEIDER
Circuit breaker, ComPacT NSX400F, 36kA/415VAC, 4 poles, MicroLogic Vigi 4.3-AB trip unit 400A - C40F44B400
C40F44B400
€2,357.90 Excl. Tax
€2,829.48 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | ComPacT new generation |
---|---|
Product name: | ComPacT NSX new generation |
Range of product: | ComPacT NSX400...630 new generation |
Device short name: | NSX400F |
Product or component type: | Earth leakage circuit breaker |
Device application: | Special application |
Poles description: | 4P |
Protected poles description: | 4D3D + N/23D |
Neutral position: | Left |
[In] rated current: | 400 A at 40 °C |
[Ue] rated operational voltage: | 440 V AC 50/60 Hz |
Network type: | AC |
Network frequency: | 50/60 Hz |
Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
Utilisation category: | Category A |
Breaking capacity: | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking capacity code: | F 36 kA 415 V AC |
Trip unit name: | Micrologic 4.3 AB |
Trip unit technology: | Electronic |
Trip unit protection functions: | LSoIR |
Control type: | Toggle |
Mounting mode: | Fixed |
[Ui] rated insulation voltage: | 500 V AC 50/60 Hz |
---|---|
[Uimp] rated impulse withstand voltage: | 8 kV |
[Ics] rated service breaking capacity: | 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-230 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 500 V AC 50/60 Hz conforming to IEC 60947-210 kA at 525 V AC 50/60 Hz conforming to IEC 60947-210 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Mechanical durability: | 15000 cycles |
Electrical durability: | 12000 cycles at 440 V In/26000 cycles at 440 V In6000 cycles at 690 V In/23000 cycles at 690 V In |
Power dissipation per pole: | 25.6 W N25.6 W L1 and L322.4 W L2 |
Mounting support: | Backplate |
Mounting position: | Horizontal and verticalFlat on the back |
Upside connection: | Front |
Downside connection: | Front |
Connection pitch: | 45 mm |
Protection type: | L |
Trip unit rating: | 400 A at 40 °C |
Long time pick-up adjustment type Ir: | Adjustable 9 settings |
Long time pick-up adjustment range: | 260...400 A |
Long time delay adjustment type: | Fixed |
[tr] long-time delay adjustment range: | 400 s at 1.5 x Ir16 s at 6 x Ir11 s at 7.2 x Ir |
Neutral protection setting: | 0.5 x Ir (3D + N/2)1 x Ir (4D)No protection (3D) |
Thermal memory: | 20 minutes before and after tripping |
Short-time pick-up adjustment type Isd: | Adjustable |
[Isd] short-time pick-up adjustment range: | 1.5...10 x Ir |
Short-time delay adjustment type: | Fixed |
[tsd] short-time delay adjustment range: | 0.02 s |
Instantaneous pick-up adjustment type Ii: | Fixed |
Instantaneous pick-up adjustment range: | 4800 A |
Earth-leakage protection: | Integrated |
Earth-leakage protection class: | Class A |
Residual earth-leakage sensitity adjustment type: | Adjustable |
[I?n] residual earth-leakage sensitive adjustment: | 300 mA500 mA1 A3 A5 A10 A |
Operating mode: | OFF using the I?n rotary switch |
Residual earth-leakage time delay adjustment type: | Adjustable |
[?t] residual earth-leakage time delay adjustment: | 0 ms60 ms150 ms500 ms1 s |
Zone selective interlocking ZSI: | Without |
Number of slots: | 6 slot(s) |
Local signalling: | Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload |
Width: | 185 mm |
Height: | 255 mm |
Depth: | 110 mm |
Net weight: | 7.9 kg |
Compatibility code: | NSX400 |
In short
Reference C40F44B400
Product Name Circuit breaker, ComPacT NSX400F, 36kA/415VAC, 4 poles, MicroLogic Vigi 4.3-AB trip unit 400A - C40F44B400
Range ComPacT nouvelle génération
Related Categories