SCHNEIDER
TeSys D control relay - 5 NO - <= 690 V - 24 V DC low consumption coil - CAD50BL
CAD50BL
€43.08 Excl. Tax
€51.70 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 25 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSysTeSys Deca |
---|---|
Range of product: | TeSys D control relay |
Product name: | TeSys CAD |
Product or component type: | Control relay |
Device short name: | CAD |
Contactor application: | Control circuit |
Utilisation category: | AC-15AC-14DC-13 |
---|---|
Pole contact composition: | 5 NO |
[Ue] rated operational voltage: | |
Control circuit type: | DC low consumption |
[Uc] control circuit voltage: | 24 V DC |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
[Ith] conventional free air thermal current: | 10 A (at 60 °C) |
Irms rated making capacity: | 140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1 |
[Icw] rated short-time withstand current: | 100 A - 1 s120 A - 500 ms140 A - 100 ms |
Associated fuse rating: | 10 A gG conforming to IEC 60947-5-1 |
[Ui] rated insulation voltage: | 600 V UL certified600 V CSA certified690 V conforming to IEC 60947-5-1 |
Mounting support: | RailPlate |
Connections - terminals: | Screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 1...4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 1...4 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endScrew clamp terminals 1 cable(s) 1...4 mm²solid without cable endScrew clamp terminals 2 cable(s) 1...4 mm²solid without cable end |
Tightening torque: | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 21.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Control circuit voltage limits: | 0.1...0.25 Uc (-40...70 °C):drop-out DC0.7...1.25 Uc (-40...60 °C):operational DC1...1.25 Uc (60...70 °C):operational DC |
Operating time: | 65...88 ms coil energisation and NO closing14...25 ms coil de-energisation and NO opening |
Mechanical durability: | 30 Mcycles |
Maximum operating rate: | 180 cyc/mn |
Time constant: | 40 ms |
Inrush power in W: | 2.4 W (at 20 °C) |
Hold-in power consumption in W: | 2.4 W at 20 °C |
Minimum switching voltage: | 17 V |
Minimum switching current: | 5 mA |
Non-overlap time: | 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact |
Insulation resistance: | > 10 MOhm |
Mechanical robustness: | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Height: | 77 mm |
Width: | 45 mm |
Depth: | 93 mm |
Product weight: | 0.58 kg |
Compatibility code: | CAD |
In short
Reference CAD50BL
Product Name TeSys D control relay - 5 NO - <= 690 V - 24 V DC low consumption coil - CAD50BL
Range TeSys
Related Categories