Technical informations
Width in Number of Modular Spacings: 2.0
Product Net Width: 35 mm
Product Net Height: 88 mm
Product Net Depth / Length: 69 mm
Product Net Weight: 0.25 kg
Pole Net Weight: 0.125 kg
Built-In Depth (t2): 69 mm
Dimension Diagram: 2CDC022007F0010
Standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077
Tripping Characteristic: C
Rated Operational Voltage: acc. to IEC 60898-1 400 V AC acc. to IEC 60898-1 400 V AC acc. to IEC 60947-2 440 V AC
Operational Voltage: Maximum (Incl. Tolerance) 125 V DC Maximum (Incl. Tolerance) 440 V AC Minimum 12 V AC Minimum 12 V DC
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp): 4 kV at 2000 m 5 kV at Sea Level 6.2 kV
Dielectric Test Voltage: 50/60 Hz, 1 min 2 kV
Input Voltage Type: AC/DC
Rated Current (In): 40 A
Rated Short-Circuit Capacity: (AC) 6 kA (DC) 6 kA (400 V AC) 6 kA (400 V) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu): (125 V DC) 10 kA (230 V AC) 20 kA (400 V AC) 10 kA (440 V AC) 10 kA (48 V DC) 20 kA (230 V) 20 kA (400 V) 10 kA
Rated Conditional Short-Circuit Current (Inc): (230 V) 20 kA (400 V) 20 kA
Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 15 kA (400 V AC) 7.5 kA (440 V AC) 7.5 kA
Frequency (f): 50 Hz
Rated Frequency (f): 50 / 60 Hz
Power Loss: 2.6 W at Rated Operating Conditions per Pole 1,3 W
Power Supply Connection: Arbitrary
Contact Position Indication: Red ON / Green OFF
Energy Limiting Class: 3
Electrical Endurance: 10000 AC cycle
Mechanical Endurance: 20000 cycle
Number of Protected Poles: 2
Number of Poles: 2
Overvoltage Category: III
Tightening Torque: 2.8 N·m
Mounting Type: DIN-Rail
Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
Actuator Marking: I / O
Actuator Material: Insulation Group II, Black, Sealable
Housing Material: Insulation Group II, RAL 7035
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position: any
Recommended Screw Driver: Pozidriv 2
Accessories Available: Yes
Connecting Capacity: Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Rigid 0.75 ... 35 mm² Stranded 0.75 ... 35 mm²
Installation Size: acc. to DIN 43880 1
Wire Stripping Length: 12.5 mm
Terminal Type: Screw Terminals