Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Environmental
- Ambient Air Temperature: Operation -25 ... +55 °C Storage -40 ... +70 °C
- Degree of Protection: IP20 IP40 Enclosure with Cover IP40
- Pollution Degree: 3
- Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
- Resistance to Vibrations: 20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
- Resistance to Shock acc. to IEC 60068-2-27: 25g 2 shocks 13 ms
Dimensions
- Width in Number of Modular Spacings: 2
- Product Net Width: 35 mm
- Product Net Height: 88 mm
- Product Net Depth / Length: 69 mm
- Product Net Weight: 0.25 kg
- Pole Net Weight: 0.125 kg
- Built-In Depth (t2): 69 mm
Technical
- Standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077
- Tripping Characteristic: Z
- Rated Operational Voltage: acc. to IEC 60898-1 400 V AC acc. to IEC 60898-1 400 V acc. to IEC 60947-2 440 V AC
- Operational Voltage: Maximum (Incl. Tolerance) 125 V DC Maximum (Incl. Tolerance) 440 V AC
- Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
- Rated Impulse Withstand Voltage (Uimp): 4 kV at 2000 m 5 kV at Sea Level 6.2 kV
- Dielectric Test Voltage: 50/60 Hz, 1 min: 2 kV
- Input Voltage Type: AC/DC
- Rated Current (In): 4 A
- Rated Short-Circuit Capacity: (AC) 6 kA (DC) 6 kA (400 V AC) 6 kA (400 V) 6 kA Rated Ultimate Short-Circuit Breaking Capacity (Icu): (125 V DC) 10 kA (230 V AC) 20 kA (400 V AC) 10 kA (440 V AC) 10 kA (48 V DC) 20 kA (230 V) 20 kA (400 V) 10 kA
- Rated Conditional Short-Circuit Current (Inc): (230 V) 20 kA (400 V) 20 kA
- Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 15 kA (400 V AC) 7.5 kA (440 V AC) 7.5 kA
- Frequency (f): 50 Hz
- Rated Frequency (f): 50 / 60 Hz
- Power Loss: 4.8 W at Rated Operating Conditions per Pole 2.4 W
- Power Supply Connection: Arbitrary
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 20000 AC cycle
- Mechanical Endurance: 20000 cycle
- Number of Protected Poles: 2
- Number of Poles: 2
- Overvoltage Category: III
- Tightening Torque: 2.8 N·m
- Mounting Type: DIN-Rail
- Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
- Actuator Marking: I / O
- Actuator Material: Insulation Group II, Black, Sealable
- Housing Material: Insulation Group II, RAL 7035
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting Position: any
- Recommended Screw Driver: Pozidriv 2
- Accessories Available: Yes
- Connecting Capacity: Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Rigid 0.75 ... 35 mm² Stranded 0.75 ... 35 mm²
- Installation Size: acc. to DIN 43880 1
- Wire Stripping Length: 12.5 mm
- Terminal Type: Screw Terminals
Technical UL/CSA
- Maximum Operating Voltage UL/CSA: 110 V DC 480Y / 277 V AC
- Interrupting Rating acc. to UL1077: (277 V AC) 6 kA (480Y / 277 V AC) 6 kA (240 V) 10 kA
- Connecting Capacity UL/CSA: Busbar 18-8 AWG Conductor 18-4 AWG
- Tightening Torque UL/CSA: 18 in·lb