Technical informations
- Environmental
- Ambient Air Temperature: : Operation -25 ... +55 °C
- Storage -40 ... +70 °C : Reference Ambient Air Temperature:
- 30 °C : Degree of Protection:
- IP20 : IP40
- Enclosure with Cover IP40 : Pollution Degree:
- 3 : Environmental Conditions:
- 28 cycles : with 55 °C / 90-96 %
- and 25 °C / 95-100 % : Resistance to Vibrations:
- 20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz : Resistance to Shock acc. to IEC 60068-2-27:
- 25g 2 shocks 13 ms
- Dimensions
- Width in Number of Modular Spacings: :3.0
- Product Net Width: 52.5 mm
- Product Net Height: 88 mm
- Product Net Depth / Length: 69 mm
- Product Net Weight: : 0.375 kg
- Pole Net Weight: :0.125 kg
- Built-In Depth (t2): 69 mm
- Dimension Diagram: :2CDC022007F0010
Standards: | IEC/EN 60898 -1 IEC/EN 60947 - UL 1077" |
---|---|
Tripping Characteristic: | D |
Rated Operational Voltage: | acc. to IEC 60898-1 400 V AC - acc. to IEC 60898-1 400 V - acc. to IEC 60947-2 440 V AC |
Operational Voltage: | Maximum (Incl. Tolerance) 440 V AC - Minimum 12 V AC - Minimum 12 V DC" |
Rated Insulation Voltage (Ui): | acc. to IEC/EN 60664-1 440 V |
Rated Impulse Withstand Voltage (Uimp): | 4 kV at 2000 m 5 kV at Sea Level 6.2 kV" |
Dielectric Test Voltage: | 50/60 Hz, 1 min 2 kV |
Input Voltage Type: | AC/DC |
Rated Current (In): | 25 A |
Rated Short-Circuit Capacity: | (AC) 6 kA - (DC) 6 kA - (400 V AC) 6 kA - (400 V) 6 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (230 V AC) 20 kA - (400 V AC) 10 kA - (440 V AC) 10 kA - (230 V) 20 kA - (400 V) 10 kA |
Rated Conditional Short-Circuit Current (Inc): | (230 V) 10 kA - (400 V) 20 kA |
Rated Service Short-Circuit Breaking Capacity (Ics): | (230 V AC) 15 kA - (400 V AC) 7.5 kA - (440 V AC) 7.5 kA |
Rated Frequency (f): | 50 / 60 Hz |
Power Loss: | 9.3 W at Rated Operating Conditions per Pole 3.1 W |
Power Supply Connection: | Arbitrary |
Contact Position Indication: | Red ON / Green OFF |
Energy Limiting Class: | 3 |
Electrical Endurance: | 20000 AC cycle |
Mechanical Endurance: | 20000 cycle |
Number of Protected Poles: | 3 |
Number of Poles: | 3 |
Overvoltage Category: | III |
Tightening Torque: | 2.8 N·m |
Mounting Type: | DIN-Rail |
Screw Terminal Type: | Failsafe Bi-directional Cylinder-lift Terminal |
Actuator Marking: | I / O |
Actuator Material: | Insulation Group II, Black, Sealable |
Housing Material: | Insulation Group II, RAL 7035 |
Mounting on DIN Rail: | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 - TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position: | any |
Recommended Screw Driver: | Pozidriv 2 |
Accessories Available: | Yes |
Connecting Capacity: | Busbar 10 / 10 mm² - Flexible with Ferrule 0.75 ... 25 mm² - Flexible 0.75 ... 25 mm² - Rigid 0.75 ... 35 mm² - Rigid 0.75 ... 35 mm² - Stranded 0.75 ... 35 mm² |
Installation Size: | acc. to DIN 43880 1 |
Wire Stripping Length: | 12.5 mm |
Terminal Type: | Screw Terminals |