Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
ABB

Circuit breaker S200 3P D 25 6kA - ABB2CDS253001R0251

ABB2CDS253001R0251

€38.91 Excl. Tax
€46.69 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
  • Environmental
    • Ambient Air Temperature: : Operation -25 ... +55 °C
    • Storage -40 ... +70 °C : Reference Ambient Air Temperature:
    • 30 °C : Degree of Protection:
    • IP20 : IP40
    • Enclosure with Cover IP40 : Pollution Degree:
    • 3 : Environmental Conditions:
    • 28 cycles : with 55 °C / 90-96 %
    • and 25 °C / 95-100 % : Resistance to Vibrations:
    • 20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz : Resistance to Shock acc. to IEC 60068-2-27:
    • 25g 2 shocks 13 ms
    • Dimensions
      • Width in Number of Modular Spacings: :3.0
      • Product Net Width: 52.5 mm
      • Product Net Height: 88 mm
      • Product Net Depth / Length: 69 mm
      • Product Net Weight: : 0.375 kg
      • Pole Net Weight: :0.125 kg
      • Built-In Depth (t2): 69 mm
      • Dimension Diagram: :2CDC022007F0010
      Standards: IEC/EN 60898 -1 IEC/EN 60947 - UL 1077"
      Tripping Characteristic: D
      Rated Operational Voltage: acc. to IEC 60898-1 400 V AC - acc. to IEC 60898-1 400 V - acc. to IEC 60947-2 440 V AC
      Operational Voltage: Maximum (Incl. Tolerance) 440 V AC - Minimum 12 V AC - Minimum 12 V DC"
      Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
      Rated Impulse Withstand Voltage (Uimp): 4 kV at 2000 m 5 kV at Sea Level 6.2 kV"
      Dielectric Test Voltage: 50/60 Hz, 1 min 2 kV
      Input Voltage Type: AC/DC
      Rated Current (In): 25 A
      Rated Short-Circuit Capacity: (AC) 6 kA - (DC) 6 kA - (400 V AC) 6 kA - (400 V) 6 kA
      Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 20 kA - (400 V AC) 10 kA - (440 V AC) 10 kA - (230 V) 20 kA - (400 V) 10 kA
      Rated Conditional Short-Circuit Current (Inc): (230 V) 10 kA - (400 V) 20 kA
      Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 15 kA - (400 V AC) 7.5 kA - (440 V AC) 7.5 kA
      Rated Frequency (f): 50 / 60 Hz
      Power Loss: 9.3 W at Rated Operating Conditions per Pole 3.1 W
      Power Supply Connection: Arbitrary
      Contact Position Indication: Red ON / Green OFF
      Energy Limiting Class: 3
      Electrical Endurance: 20000 AC cycle
      Mechanical Endurance: 20000 cycle
      Number of Protected Poles: 3
      Number of Poles: 3
      Overvoltage Category: III
      Tightening Torque: 2.8 N·m
      Mounting Type: DIN-Rail
      Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
      Actuator Marking: I / O
      Actuator Material: Insulation Group II, Black, Sealable
      Housing Material: Insulation Group II, RAL 7035
      Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 - TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
      Mounting Position: any
      Recommended Screw Driver: Pozidriv 2
      Accessories Available: Yes
      Connecting Capacity: Busbar 10 / 10 mm² - Flexible with Ferrule 0.75 ... 25 mm² - Flexible 0.75 ... 25 mm² - Rigid 0.75 ... 35 mm² - Rigid 0.75 ... 35 mm² - Stranded 0.75 ... 35 mm²
      Installation Size: acc. to DIN 43880 1
      Wire Stripping Length: 12.5 mm
      Terminal Type: Screw Terminals
      In short
      Reference ABB2CDS253001R0251
      Product Name Circuit breaker S200 3P D 25 6kA - ABB2CDS253001R0251
      Related Categories