Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews

Connection Circuit Breakers

The connection circuit breaker plays an essential role in electrical installations. It protects the electrical…

LEG401011
LEGRAND
Enedis - 60A 500mA Instantaneous Tetrapolar Differential Circuit Breaker
LEG401011
€172.61 €143.84
available In stock
dispatched within 24/48h
LEG401013
LEGRAND
Disjoncteur de branchement Enedis tétrapolaire différentiel 500mA sélectif - 60A - 401013
LEG401013
€280.04 €233.37
available In stock
dispatched within 24/48h
R9FS645
SCHNEIDER
Earth leakage circuit breaker for service connection DB60 - 1P+N - 45A - 500mA S - R9FS645
R9FS645
€128.39 €106.99
available In stock
dispatched within 24/48h
R9FN645
SCHNEIDER
Circuit breaker for service connection - DB60 - 1P+N - 45A - R9FN645
R9FN645
€95.98 €79.98
preorder Supply in process
LEG401051
LEGRAND
Disjoncteur de branchement Enedis bipolaire différentiel 500mA instantané intensité 60A non réglable - 401051
LEG401051
€112.97 €94.14
available In stock
dispatched within 24/48h
R9FS660
SCHNEIDER
Earth leakage circuit breaker for service connection DB60 - 1P+N - 60A - 500mA S - R9FS660
R9FS660
€180.55 €150.46
available In stock
dispatched within 24/48h
LEG401010
LEGRAND
Disjoncteur branchement Enedis tétrapolaire différentiel 500mA instantané - 30A - 401010
LEG401010
€164.28 €136.90
available In stock
dispatched within 24/48h
R9FT660
SCHNEIDER
Earth leakage circuit breaker for service connection DB60 - 1P+N - 60A - 500mA - R9FT660
R9FT660
€134.20 €111.83
available In stock
dispatched within 24/48h
LEG401006
LEGRAND
Disjoncteur de branchement Enedis bipolaire différentiel 500mA sélectif intensité 60A non réglable - 401006
LEG401006
€181.91 €151.59
available In stock
dispatched within 24/48h
LEG401000
LEGRAND
Disjoncteur de branchement Enedis bipolaire différentiel 500mA instantané - 45A - 401000
LEG401000
€76.68 €63.90
available In stock
dispatched within 24/48h
R9FT645
SCHNEIDER
Earth leakage circuit breaker for service connection DB60 - 1P+N - 45A - 500mA - R9FT645
R9FT645
€75.05 €62.54
available In stock
dispatched within 24/48h
LEG401012
LEGRAND
Disjoncteur de branchement Enedis tétrapolaire différentiel 500mA sélectif - 30A - 401012
LEG401012
€187.19 €155.99
available In stock
dispatched within 24/48h
R9FN660
SCHNEIDER
Circuit breaker for service connection - DB60 - 1P+N - 60A - R9FN660
R9FN660
€138.23 €115.19
preorder Supply in process
LEG401009
LEGRAND
Disjoncteur de branchement Enedis bipolaire non différentiel - 90A - 401009
LEG401009
€344.64 €287.20
preorder Supply in process
LEG401015
LEGRAND
Disjoncteur de branchement Enedis tétrapolaire non différentiel - 60A - 401015
LEG401015
€265.73 €221.44
preorder Supply in process
LEG401003
LEGRAND
Disjoncteur de branchement Enedis bipolaire différentiel 500mA sélectif - 45A - 401003
LEG401003
€154.09 €128.41
available In stock
dispatched within 24/48h

What is a connection circuit breaker?

There are two types of circuit breaker: instantaneous and selective. Instantaneous circuit breakers trip immediately if there is a problem on the electricity network, while selective circuit breakers operate with a slight delay. The connection circuit-breaker is installed on the technical housing duct upstream of the electrical box. In addition, the connection circuit-breaker limits the power consumed throughout the dwelling, depending on the contract you have with your energy supplier.

Role and location of the connection circuit breaker

The connection circuit breaker acts as the interface between the electrical installation in your home and the electricity distribution network managed by Enedis. There is a property boundary between your private network and that of the distributor.

Types of connection circuit breaker

Connection circuit breakers come in single-phase and three-phase versions. Single-phase has two electrical connection terminals (1 phase and 1 neutral), while three-phase has four (3 phases and 1 neutral). Each type is designed to meet specific individual or industrial uses.
To choose the right connection circuit breaker, it's essential to consider the energy requirements of your home. While single-phase circuit breakers offer a power range from 3 to 18 kVA, three-phase circuit breakers cover a range from 6 to 36 kVA.
It should be noted that most homes are equipped with single-phase systems, as their power requirements are generally lower than those of businesses.
What's more, One-Elec sells both differential and non-differential circuit breakers.

Some references to be found on One-Elec

The BACO low-voltage circuit breaker (ref. LEG401000) is a 250V~ bipolar device designed for limited-power tariffs (blue tariff) from 3kVA to 36kVA, with a rated current of 45A. Its main functions include disconnection and isolation of the installation, protection against overloads and short circuits, and rating adjustment to limit power according to the contract. It can be sealed and has an instantaneous 500mA differential version to protect people against indirect contact and prevent the risk of fire. The current rating is adjustable to 15A, 30A or 45A, and its Enedis nomenclature number is 69 30 044. This circuit breaker is approved to NF C 62-411.
For greater convenience, particularly in second homes, this circuit breaker can be combined with reference SURT66006, enabling it to be reset remotely, for example after a storm.
A four-pole version of this circuit breaker is also available under reference LEG401011.
For larger installations requiring a monitored power tariff (yellow tariff) from 36 to 250kVA, the connection circuit breaker referenced KIT_AGCP_160 is recommended.

Standards and regulations for connection circuit breakers

Located upstream of your electrical installation and downstream of the meter, it delimits the zone governed by standard NF C15-100 (private network) from the zone governed by standard NF C14-100 (public network).
This distinction means that you can work on all the parameters of your electrical installation that depend on the circuit-breaker, either yourself or by calling in a professional electrician. On the other hand, everything upstream of the circuit-breaker is managed exclusively by your electricity supplier.

Installing a connection circuit breaker

The installation and operation of a connection circuit breaker is reserved for professionals and must not be carried out by private individuals. In the residential sector, this device is installed and sealed by Enedis, which prevents any unauthorised intervention.

Choosing and maintaining connection circuit breakers

For the best possible electrical installation, choose circuit breakers from brands such as Legrand or Schneider. These brands are renowned for their quality, reliability and durability, all of which are essential when choosing electrical equipment.
At One-Elec, you'll find a selection of connection circuit breakers from these two brands. We guarantee excellent value for money and quality customer service. If necessary, our technical service is available to answer your questions.
We also strongly advise you to check your electrical panel and circuit breakers regularly. These installations can show signs of wear and tear or malfunction over time, and it's wise to pay attention to this. Regular maintenance, ideally carried out by a professional, will ensure the safety and efficiency of your electrical installation.

Find your connection circuit breaker on one-elec.com

Choosing the right connection circuit breaker and, above all, installing it are two essential steps in ensuring a safe and reliable electrical installation. By opting for quality brands such as Legrand and Schneider, available at One-Elec, you are choosing high-quality, efficient equipment. What's more, by entrusting the installation to a qualified professional, you guarantee optimum protection for your domestic or professional electrical network. If you have any questions, contact us!