Technical informations
Range: TeSys Deca
Range of product: TeSys GV2
Product name: TeSys GV2TeSys Deca
Product or component type: Motor circuit breaker
Device short name: GV2ME
Device application: Motor protection
Trip unit technology: Thermal-magnetic
Poles description: 3P
Network type: AC
Utilisation category: Category A conforming to IEC 60947-2AC-3 conforming to IEC 60947-4-1AC-3e conforming to IEC 60947-4-1
Network frequency: 50/60 Hz conforming to IEC 60947-4-1
Fixing mode: 35 mm symmetrical DIN rail: clippedPanel: screwed (with adaptor plate)
Motor power kW: 0.09 kW at 400/415 V AC 50/60 Hz
Breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control type: Push-button
[In] rated current: 0.4 A
Thermal protection adjustment range: 0.25...0.4 A conforming to IEC 60947-4-1
Magnetic tripping current: 5 A
[Ith] conventional free air thermal current: 0.4 A conforming to IEC 60947-4-1
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Suitability for isolation: Yes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole: 2.5 W
Mechanical durability: 100000 cycles
Electrical durability: 100000 cycles for AC-3 at 415 V In100000 cycles for AC-3e at 415 V In
Maximum operating rate: 25 cyc/h
Rated duty: Continuous conforming to IEC 60947-4-1
Direct connector: Without
Width: 45 mm
Height: 101 mm
Depth: 78.5 mm
Net weight: 0.28 kg
Colour: Dark grey
Compatibility code: GV2ME