Technical informations
Range: TeSys Deca
Range of product: TeSys GV2TeSys Deca
Product name: TeSys Deca
Product or component type: Circuit breaker
Device short name: GV2ME
Device application: Motor
Poles description: 3P
Network type: AC
Control type: Push-button
Motor power kW: 0.75 kW at 400/415 V AC 50/60 Hz1.1 kW at 500 V AC 50/60 Hz1.5 kW at 690 V AC 50/60 Hz
[In] rated current: 2.5 A
Magnetic tripping current: 33.5 A
Thermal protection adjustment range: 1.6...2.5 A conforming to IEC 60947-4-1
Suitability for isolation: Yes conforming to IEC 60947-1 § 7-1-6
Utilisation category: AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2
Connections - terminals: Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable endPower circuit: screw clamp terminal 2 cable(s) 1...6 mm²solidPower circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end
Quantity per set: Set of 20
Network frequency: 50/60 Hz
Mounting mode: Fixed
Mounting support: PlateRail
Mounting position: VerticalHorizontal
Auxiliary contact composition: 1 NO + 1 NC front
Trip unit technology: Thermal-magnetic
Phase failure sensitivity: Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
[Ue] rated operational voltage: 600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2600 V AC 50/60 Hz conforming to CSA C22.2 No 14
[Ui] rated insulation voltage: 600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2600 V AC 50/60 Hz conforming to CSA C22.2 No 14
[Ith] conventional free air thermal current: 2.5 A conforming to IEC 60947-4-1
Network frequency: 50/60 Hz conforming to CSA50/60 Hz conforming to UL50/60 Hz conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
Power dissipation per pole: 2.5 W
Mechanical durability: 100000 cycles
Electrical durability: 100000 cycles for AC-3 at 440 V In100000 cycles for AC-3 at 440 V In/2
Maximum number of switchings: 25 cyc/h
Rated duty: Continuous conforming to IEC 60947-4-1
Tightening torque: 1.7 N.m - on screw clamp terminal - cable 1...4 mm²1.7 N.m - on screw clamp terminal - cable 1...6 mm²1.7 N.m - on screw clamp terminal - cable 1.5...6 mm²
Breaking capacity: Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-275 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Height: 89 mm
Width: 44.5 mm
Depth: 78.2 mm
Product weight: 0.26 kg