SCHNEIDER
motor circuit breaker, TeSys Deca , 1.6...2.5 A , 3 3d , thermal magnetic trip unit - GV2ME07AE11TQ
GV2ME07AE11TQ
€55.39 Excl. Tax
€66.47 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSys Deca |
---|---|
Range of product: | TeSys GV2TeSys Deca |
Product name: | TeSys Deca |
Product or component type: | Circuit breaker |
Device short name: | GV2ME |
Device application: | Motor |
Poles description: | 3P |
Network type: | AC |
Control type: | Push-button |
Motor power kW: | 0.75 kW at 400/415 V AC 50/60 Hz1.1 kW at 500 V AC 50/60 Hz1.5 kW at 690 V AC 50/60 Hz |
[In] rated current: | 2.5 A |
Magnetic tripping current: | 33.5 A |
Thermal protection adjustment range: | 1.6...2.5 A conforming to IEC 60947-4-1 |
Suitability for isolation: | Yes conforming to IEC 60947-1 § 7-1-6 |
Utilisation category: | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 |
Connections - terminals: | Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable endPower circuit: screw clamp terminal 2 cable(s) 1...6 mm²solidPower circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end |
Quantity per set: | Set of 20 |
Network frequency: | 50/60 Hz |
---|---|
Mounting mode: | Fixed |
Mounting support: | PlateRail |
Mounting position: | VerticalHorizontal |
Auxiliary contact composition: | 1 NO + 1 NC front |
Trip unit technology: | Thermal-magnetic |
Phase failure sensitivity: | Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 |
[Ue] rated operational voltage: | 600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2600 V AC 50/60 Hz conforming to CSA C22.2 No 14 |
[Ui] rated insulation voltage: | 600 V AC 50/60 Hz conforming to UL 508690 V AC 50/60 Hz conforming to IEC 60947-2600 V AC 50/60 Hz conforming to CSA C22.2 No 14 |
[Ith] conventional free air thermal current: | 2.5 A conforming to IEC 60947-4-1 |
Network frequency: | 50/60 Hz conforming to CSA50/60 Hz conforming to UL50/60 Hz conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947-2 |
Power dissipation per pole: | 2.5 W |
Mechanical durability: | 100000 cycles |
Electrical durability: | 100000 cycles for AC-3 at 440 V In100000 cycles for AC-3 at 440 V In/2 |
Maximum number of switchings: | 25 cyc/h |
Rated duty: | Continuous conforming to IEC 60947-4-1 |
Tightening torque: | 1.7 N.m - on screw clamp terminal - cable 1...4 mm²1.7 N.m - on screw clamp terminal - cable 1...6 mm²1.7 N.m - on screw clamp terminal - cable 1.5...6 mm² |
Breaking capacity: | Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity: | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-275 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Height: | 89 mm |
Width: | 44.5 mm |
Depth: | 78.2 mm |
Product weight: | 0.26 kg |
In short
Reference GV2ME07AE11TQ
Product Name motor circuit breaker, TeSys Deca , 1.6...2.5 A , 3 3d , thermal magnetic trip unit - GV2ME07AE11TQ
Device function Moteur
Related Categories