Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals - GV2P06

GV2P06

€62.89 Excl. Tax
€75.47 Inc. Tax
available In stock more than 100 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range: TeSysTeSys Deca
Range of product: TeSys GV2
Product name: TeSys GV2TeSys Deca
Product or component type: Circuit breaker
Device short name: GV2P
Device application: Motor
Trip unit technology: Thermal-magnetic
Poles description: 3P
Network type: AC
Utilisation category: AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2
Network frequency: 50/60 Hz conforming to IEC 60947-4-1
Fixing mode: 35 mm symmetrical DIN rail: clippedPanel: screwed (with 2 x M4 screws)
Operating position: Any position
Motor power kW: 0.37 kW at 400/415 V AC 50/60 Hz0.37 kW at 500 V AC 50/60 Hz0.75 kW at 690 V AC 50/60 Hz0.55 kW at 400/415 V AC 50/60 Hz0.55 kW at 500 V AC 50/60 Hz
Breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Control type: Rotary knob
[In] rated current: 1.6 A
Trip unit rating: 1...1.6 A
Magnetic tripping current: 22.5 A
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current: 1.6 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
Power dissipation per pole: 2.5 W
Mechanical durability: 100000 cycles
Electrical durability: 100000 cycles for AC-3 at 440 V
Maximum operating rate: 25 cyc/h
Rated duty: Continuous conforming to IEC 60947-4-1
Direct connector: Without
Tightening torque: 1.7 N.m on screw clamp terminals
Suitability for isolation: Yes conforming to IEC 60947-1
Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Height: 89 mm
Width: 45 mm
Depth: 97 mm
Colour: Dark grey
Compatibility code: GV2P
In short
Reference GV2P06
Product Name Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals - GV2P06
Range TeSys
Device function Moteur
Related Categories