SCHNEIDER
Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals - GV2P08
GV2P08
€62.89 Excl. Tax
€75.47 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSysTeSys Deca |
---|---|
Range of product: | TeSys GV2 |
Product name: | TeSys GV2TeSys Deca |
Product or component type: | Circuit breaker |
Device short name: | GV2P |
Device application: | Motor |
Trip unit technology: | Thermal-magnetic |
Poles description: | 3P |
---|---|
Network type: | AC |
Utilisation category: | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 |
Network frequency: | 50/60 Hz conforming to IEC 60947-4-1 |
Fixing mode: | 35 mm symmetrical DIN rail: clippedPanel: screwed (with 2 x M4 screws) |
Operating position: | Any position |
Motor power kW: | 1.1 kW at 400/415 V AC 50/60 Hz1.5 kW at 500 V AC 50/60 Hz2.2 kW at 690 V AC 50/60 Hz |
Breaking capacity: | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity: | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
Control type: | Rotary knob |
[In] rated current: | 4 A |
Trip unit rating: | 2.5...4 A |
Magnetic tripping current: | 51 A |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ith] conventional free air thermal current: | 4 A conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947-2 |
Power dissipation per pole: | 2.5 W |
Mechanical durability: | 100000 cycles |
Electrical durability: | 100000 cycles for AC-3 at 440 V |
Maximum operating rate: | 25 cyc/h |
Rated duty: | Continuous conforming to IEC 60947-4-1 |
Direct connector: | Without |
Tightening torque: | 1.7 N.m on screw clamp terminals |
Suitability for isolation: | Yes conforming to IEC 60947-1 |
Phase failure sensitivity: | Yes conforming to IEC 60947-4-1 |
Height: | 89 mm |
Width: | 45 mm |
Depth: | 97 mm |
Colour: | Dark grey |
Compatibility code: | GV2P |
In short
Reference GV2P08
Product Name Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals - GV2P08
Range TeSys
Device function Moteur
Related Categories