Technical informations
Range: TeSys
Range of product: TeSys GV2
Product name: TeSys GV2
Product or component type: Circuit breaker
Device short name: GV2RT
Device application: TransformerMotor
Trip unit technology: Thermal-magnetic
Poles description: 3P
Network type: AC
Utilisation category: AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2
Network frequency: 50/60 Hz conforming to IEC 60947-4-1
Fixing mode: 35 mm symmetrical DIN rail: clippedPanel: screwed (with adaptor plate)
Operating position: Any position
Motor power kW: 1.5 kW at 220/230 V AC 50/60 Hz motor protection high peak current2.2 kW at 220/230 V AC 50/60 Hz motor protection high peak current3 kW at 400/415 V AC 50/60 Hz motor protection high peak current4 kW at 400/415 V AC 50/60 Hz motor protection high peak current4 kW at 440 V AC 50/60 Hz motor protection high peak current4 kW at 500 V AC 50/60 Hz motor protection high peak current5.5 kW at 500 V AC 50/60 Hz motor protection high peak current5.5 kW at 690 V AC 50/60 Hz motor protection high peak current7.5 kW at 690 V AC 50/60 Hz motor protection high peak current2.5 kW at 230/240 V AC 50/60 Hz transformer protection4 kW at 400/415 V AC 50/60 Hz transformer protection5 kW at 400/415 V AC 50/60 Hz transformer protection5 kW at 440 V AC 50/60 Hz transformer protection5 kW at 500 V AC 50/60 Hz transformer protection6.3 kW at 500 V AC 50/60 Hz transformer protection
Breaking capacity: 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-23 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
Control type: Toggle
[In] rated current: 10 A
Trip unit rating: 6...10 A
Magnetic tripping current: 200 A
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current: 10 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
Power dissipation per pole: 2.5 W
Mechanical durability: 100000 cycles
Electrical durability: 100000 cycles for AC-3 at 440 V
Maximum operating rate: 25 cyc/h
Rated duty: Continuous conforming to IEC 60947-4-1
Direct connector: Without
Tightening torque: 1.7 N.m on screw clamp terminals
Suitability for isolation: Yes conforming to IEC 60947-1
Height: 89 mm
Width: 45 mm
Depth: 78.5 mm
Compatibility code: GV2RT