Technical informations
Range: TeSys
Product name: TeSys GV4
Product or component type: Circuit breaker
Device short name: GV4L
Device application: Motor protection
Poles description: 3P
Utilisation category: Category A
Trip unit technology: MagneticElectronic
Protection type: Short-circuit
[In] rated current: 25 A
Breaking capacity: Icu 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2Icu 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2Icu 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Icu 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity: 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-225 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-220 kA at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit rating: 150...350 A
Control type: Rotary handle
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
Motor power kW: 7.5 kW at 660...690 V AC 50/60 Hz5.5 kW at 400...415 V AC 50/60 Hz7.5 kW at 500 V AC 50/60 Hz9 kW at 660...690 V AC 50/60 Hz11 kW at 660...690 V AC 50/60 Hz7.5 kW at 400...415 V AC 50/60 Hz9 kW at 400...415 V AC 50/60 Hz11 kW at 400...415 V AC 50/60 Hz9 kW at 500 V AC 50/60 Hz11 kW at 500 V AC 50/60 Hz15 kW at 500 V AC 50/60 Hz15 kW at 660...690 V AC 50/60 Hz18.5 kW at 660...690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
[Ui] rated insulation voltage: 800 V conforming to IEC 60947-2
Mounting mode: By screwsBy clips
Mounting support: 35 mm symmetrical DIN rail75 mm symmetrical DIN railPlate
Suitability for isolation: Yes conforming to IEC 60947-1
Mechanical durability: 40000 cycles
Electrical durability: 40000 cycles for AC-3 at 440 V In/220000 cycles for AC-3 at 440 V In
Local signalling: Green indicator for presence of auxiliary contacts
Number of slots: 1 slot(s) for alarm switch for fault signalling contact, plug-in1 slot(s) for voltage release for electrical remote tripping, plug-in1 slot(s) for auxiliary switch for open/close contact, plug-in
Rotary handle padlocking: Padlock in OFF or ON position
Connection pitch: 27 mm
Connections - terminals: Top 1 EverLink BTR screw connectors wire size 1.5...70 mm², solidTop 1 EverLink BTR screw connectors wire size 1.5...50 mm², flexibleBottom 1 EverLink BTR screw connectors wire size 2.5...95 mm², solidBottom 1 EverLink BTR screw connectors wire size 2.5...70 mm², flexible
Tightening torque: 9 N.m for 16...95 mm²5 N.m for 1.5...10 mm²
Wire stripping length: 20 mm
Quality labels: CE
Standards: EN/IEC 60947-2EN/IEC 60947-4-1
Height: 155 mm
Width: 81 mm
Depth: 165 mm
Product weight: 1.65 kg
Colour: Grey (RAL 7016)
In short
Reference GV4L25B
Product Name TeSys GV4 - magnetic circuit breaker - 25A 3P - with EverLink - GV4L25B
Range TeSys
Device function Motor protection
Related Categories