Technical informations
Range: | TeSys |
---|---|
Product name: | TeSys GV4 |
Product or component type: | Circuit breaker |
Device short name: | GV4L |
Device application: | Motor protection |
Poles description: | 3P |
Utilisation category: | Category A |
Trip unit technology: | MagneticElectronic |
Protection type: | Short-circuit |
[In] rated current: | 115 A |
Breaking capacity: | Icu 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2Icu 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2Icu 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Icu 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service breaking capacity: | 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-225 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-220 kA at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
Trip unit rating: | 690...1610 A |
Control type: | Toggle |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
---|---|
Motor power kW: | 37 kW at 400...415 V AC 50/60 Hz45 kW at 400...415 V AC 50/60 Hz55 kW at 400...415 V AC 50/60 Hz45 kW at 500 V AC 50/60 Hz55 kW at 500 V AC 50/60 Hz75 kW at 500 V AC 50/60 Hz75 kW at 660...690 V AC 50/60 Hz90 kW at 660...690 V AC 50/60 Hz110 kW at 660...690 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947-2 |
[Ui] rated insulation voltage: | 800 V conforming to IEC 60947-2 |
Mounting mode: | By clipsBy screws |
Mounting support: | Plate75 mm symmetrical DIN rail35 mm symmetrical DIN rail |
Suitability for isolation: | Yes conforming to IEC 60947-1 |
Mechanical durability: | 40000 cycles |
Electrical durability: | 10000 cycles for AC-3 at 440 V In/25000 cycles for AC-3 at 440 V In |
Local signalling: | Green indicator for presence of auxiliary contacts |
Number of slots: | 1 slot(s) for alarm switch for fault signalling contact, plug-in1 slot(s) for voltage release for electrical remote tripping, plug-in1 slot(s) for auxiliary switch for open/close contact, plug-in |
Connection pitch: | 27 mm |
Connections - terminals: | Top 1 EverLink BTR screw connectors wire size 1.5...70 mm², solidTop 1 EverLink BTR screw connectors wire size 1.5...50 mm², flexibleBottom 1 EverLink BTR screw connectors wire size 2.5...95 mm², solidBottom 1 EverLink BTR screw connectors wire size 2.5...70 mm², flexible |
Tightening torque: | 9 N.m for 16...95 mm²5 N.m for 1.5...10 mm² |
Wire stripping length: | 20 mm |
Quality labels: | CE |
Standards: | EN/IEC 60947-2EN/IEC 60947-4-1 |
Height: | 155 mm |
Width: | 81 mm |
Depth: | 116 mm |
Product weight: | 1.5 kg |
Colour: | Grey (RAL 7016) |