Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
100 products at 10% off until 18 November! Find out more
SCHNEIDER

TeSys GV4 - magnetic circuit breaker - 12.5A 3P - with EverLink - GV4LE12N

GV4LE12N

€235.03 Excl. Tax
€282.04 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range: TeSys
Product name: TeSys GV4
Product or component type: Circuit breaker
Device short name: GV4L
Device application: Motor protection
Poles description: 3P
Utilisation category: Category A
Trip unit technology: MagneticElectronic
Protection type: Short-circuit
[In] rated current: 12.5 A
Breaking capacity: Icu 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2Icu 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Icu 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2Icu 8 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity: 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-250 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 500 V AC 50/60 Hz conforming to IEC 60947-215 kA at 525 V AC 50/60 Hz conforming to IEC 60947-22 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit rating: 75...175 A
Control type: Toggle
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
Motor power kW: 3 kW at 400...415 V AC 50/60 Hz3 kW at 500 V AC 50/60 Hz5.5 kW at 660...690 V AC 50/60 Hz7.5 kW at 660...690 V AC 50/60 Hz5.5 kW at 400...415 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz7.5 kW at 500 V AC 50/60 Hz9 kW at 660...690 V AC 50/60 Hz11 kW at 660...690 V AC 50/60 Hz3.7 kW at 400...415 V AC 50/60 Hz3.7 kW at 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
[Ui] rated insulation voltage: 800 V conforming to IEC 60947-2
Mounting mode: By clipsBy screws
Mounting support: 75 mm symmetrical DIN railPlate35 mm symmetrical DIN rail
Suitability for isolation: Yes conforming to IEC 60947-1
Mechanical durability: 40000 cycles
Electrical durability: 40000 cycles for AC-3 at 440 V In/240000 cycles for AC-3 at 440 V In
Local signalling: Green indicator for presence of auxiliary contacts
Number of slots: 1 slot(s) for alarm switch for fault signalling contact, plug-in1 slot(s) for voltage release for electrical remote tripping, plug-in1 slot(s) for auxiliary switch for open/close contact, plug-in
Connection pitch: 27 mm
Connections - terminals: Top 1 EverLink BTR screw connectors wire size 1.5...70 mm², solidTop 1 EverLink BTR screw connectors wire size 1.5...50 mm², flexibleBottom 1 EverLink BTR screw connectors wire size 2.5...95 mm², solidBottom 1 EverLink BTR screw connectors wire size 2.5...70 mm², flexible
Tightening torque: 9 N.m for 16...95 mm²5 N.m for 1.5...10 mm²
Wire stripping length: 20 mm
Quality labels: CE
Standards: EN/IEC 60947-2EN/IEC 60947-4-1
Height: 155 mm
Width: 81 mm
Depth: 116 mm
Product weight: 1.5 kg
Colour: Grey (RAL 7016)
In short
Reference GV4LE12N
Product Name TeSys GV4 - magnetic circuit breaker - 12.5A 3P - with EverLink - GV4LE12N
Range TeSys
Device function Motor protection
Related Categories