SCHNEIDER
TeSys GV4 - thermal magnetic circuit breaker - 50A 3P - with Everlink - GV4PE50N
GV4PE50N
€167.06 Excl. Tax
€200.47 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSys DecaTeSys Deca |
---|---|
Range of product: | TeSys GV4 |
Device short name: | GV4PE |
Product name: | TeSys GV4TeSys Deca |
Product or component type: | Motor circuit breaker |
Device application: | Motor protection |
Trip unit technology: | Thermal-magneticElectronic |
Poles description: | 3P |
---|---|
Utilisation category: | Category A conforming to IEC 60947-2AC-3 conforming to IEC 60947-4-1 |
Operating position: | Any position |
Motor power kW: | 11 kW at 400...415 V AC 50/60 Hz15 kW at 500 V AC 50/60 Hz18.5 kW at 660...690 V AC 50/60 Hz15 kW at 400...415 V AC 50/60 Hz18.5 kW at 400...415 V AC 50/60 Hz22 kW at 400...415 V AC 50/60 Hz18.5 kW at 500 V AC 50/60 Hz22 kW at 500 V AC 50/60 Hz30 kW at 500 V AC 50/60 Hz22 kW at 660...690 V AC 50/60 Hz30 kW at 660...690 V AC 50/60 Hz37 kW at 660...690 V AC 50/60 Hz45 kW at 660...690 V AC 50/60 Hz |
Breaking capacity: | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-265 kA at 208Y/120 V AC 50/60 Hz conforming to UL 6094765 kA at 240 V AC 50/60 Hz conforming to UL 6094735 kA at 480Y/277 V AC 50/60 Hz conforming to UL 609478 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-218 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947 |
Control type: | Toggle |
[In] rated current: | 50 A |
Magnetic tripping current: | 850 A |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage: | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ith] conventional free air thermal current: | 115 A conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947-2 |
Power dissipation per pole: | 4.6 W |
Mechanical durability: | 40000 cycles |
Electrical durability: | 20000 cycles for AC-3 at 440 V In/210000 cycles for AC-3 at 440 V In |
Maximum operating rate: | 25 cyc/h |
Rated duty: | Continuous conforming to IEC 60947-4-1 |
Direct connector: | Without |
Connections - terminals: | EverLink BTR screw connectors (top) 1 cable(s) 1.5...70 mm² - solidEverLink BTR screw connectors (top) 1 cable(s) 1.5...50 mm² - flexibleEverLink BTR screw connectors (bottom) 1 cable(s) 2.5...95 mm² - solidEverLink BTR screw connectors (bottom) 1 cable(s) 2.5...70 mm² - flexible |
Tightening torque: | 9 N.m for cable 16...95 mm²5 N.m for cable 1.5...10 mm² |
Mechanical robustness: | Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
Phase failure sensitivity: | Yes conforming to IEC 60947-4-1 |
Height: | 155 mm |
Width: | 81 mm |
Depth: | 116 mm |
Net weight: | 1.45 kg |
Colour: | Grey (RAL 7016) |
Suitability for isolation: | Yes conforming to IEC 60947-1 |
In short
Reference GV4PE50N
Product Name TeSys GV4 - thermal magnetic circuit breaker - 50A 3P - with Everlink - GV4PE50N