Technical informations
Range of product: TeSys DTeSys F
Range: TeSys
Device short name: LADN
Product or component type: Auxiliary contact block
Range compatibility: TeSys D LC1D contactorTeSys D LP1D contactor
Auxiliary contacts operation: Instantaneous
Pole contact composition: 2 NO + 2 NC
Connections - terminals: Screw clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - with cable endScrew clamp terminals 1 cable 1...2.5 mm² - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - with cable endScrew clamp terminals 1 cable 1...2.5 mm² - cable stiffness: solid - without cable endScrew clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable 1...2.5 mm² - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - with cable endScrew clamp terminals 2 cable 1...2.5 mm² - cable stiffness: solid - without cable end
Mounting location: Front
[Ui] rated insulation voltage: 690 V - conforming to IEC 60947-5-1600 V - certifications CSA600 V - certifications UL
[Ue] rated operational voltage: 690 V AC 25...400 Hz
[Ith] conventional free air thermal current: 10 A at
Irms rated making capacity: 140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1
Permissible short-time rating: 100 A at -5...60 °C 1 s120 A at -5...60 °C 500 ms140 A at -5...60 °C 100 ms
Protection type: GG fuse
Associated fuse rating: 10 A gG IEC 60947-5-1
Mechanical durability: 30 Mcycles
Minimum switching current: 5 mA
Minimum switching voltage: 17 V
Non-overlap time: 1.5 ms on de-energisation (no overlap between NC and NO contact)1.5 ms on energisation (no overlap between NC and NO contact)
Overlap time: 1.5 ms
Insulation resistance: > 10 MOhm
Product weight: 0.05 kg