SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 48 V AC 50/60 Hz coil - LC1D115E7
LC1D115E7
€287.83 Excl. Tax
€345.40 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys D |
---|---|
Range: | TeSys |
Product name: | TeSys D |
Product or component type: | Contactor |
Device short name: | LC1D |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-1AC-4AC-3 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | Power circuit: Power circuit: |
[Ie] rated operational current: | 200 A (at 115 A (at |
Motor power kW: | 30 kW at 220...230 V AC 50/60 Hz (AC-3)55 kW at 380...400 V AC 50/60 Hz (AC-3)59 kW at 415...440 V AC 50/60 Hz (AC-3)75 kW at 500 V AC 50/60 Hz (AC-3)80 kW at 660...690 V AC 50/60 Hz (AC-3)65 kW at 1000 V AC 50/60 Hz (AC-3)18.5 kW at 400 V AC 50/60 Hz (AC-4) |
Motor power hp: | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors40 hp at 230/240 V AC 50/60 Hz for 3 phases motors75 hp at 460/480 V AC 50/60 Hz for 3 phases motors100 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
Control circuit type: | AC at 50/60 Hz |
[Uc] control circuit voltage: | 48 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947 |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 200 A (at 60 °C) for power circuit |
Irms rated making capacity: | 1260 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity: | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 250 A 40 °C - 10 min for power circuit550 A 40 °C - 1 min for power circuit950 A 40 °C - 10 s for power circuit1100 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
Associated fuse rating: | 250 A gG at 200 A gG at 10 A gG for signalling circuit |
Average impedance: | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
[Ui] rated insulation voltage: | Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified |
Electrical durability: | 0.8 Mcycles 200 A AC-1 at Ue 0.95 Mcycles 115 A AC-3 at Ue |
Power dissipation per pole: | 24 W AC-17.9 W AC-3 |
Protective cover: | With |
Mounting support: | PlateRail |
Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
Product certifications: | DNVCCCRINAGOSTBVGLLROS (Lloyds register of shipping)CSAUL |
Connections - terminals: | Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²solid without cable endPower circuit: connector 1 cable(s) 10...120 mm²flexible without cable endPower circuit: connector 2 cable(s) 10...50 mm²flexible without cable endPower circuit: connector 1 cable(s) 10...120 mm²flexible with cable endPower circuit: connector 2 cable(s) 10...50 mm²flexible with cable endPower circuit: connector 1 cable(s) 10...120 mm²solid without cable endPower circuit: connector 2 cable(s) 10...50 mm²solid without cable end |
Tightening torque: | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on connector hexagonal screw head 4 mm |
Operating time: | 6...20 ms opening20...50 ms closing |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 8 Mcycles |
Maximum operating rate: | 2400 cyc/h 60 °C |
Coil technology: | Built-in bidirectional peak limiting diode suppressor |
---|---|
Control circuit voltage limits: | 0.3...0.5 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40...55 °C):operational AC 50/60 Hz1...1.15 Uc (55...70 °C):operational AC 50/60 Hz |
Inrush power in VA: | 280...350 VA 60 Hz cos phi 0.8 (at 20 °C)280...350 VA 50 Hz cos phi 0.8 (at 20 °C) |
Hold-in power consumption in VA: | 2...18 VA 60 Hz cos phi 0.3 (at 20 °C)2...18 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation: | 3...8 W at 50/60 Hz |
Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact |
Insulation resistance: | > 10 MOhm for signalling circuit |
Contact compatibility: | M13 |
Compatibility code: | LC1D |
Power range: | 30...50 kW at 200...240 V 3 phases55...100 kW at 380...440 V 3 phases55...100 kW at 480...500 V 3 phases |
Motor starter type: | Direct on-line contactor |
Contactor coil voltage: | 48 V AC standard |
In short
Reference LC1D115E7
Product Name TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 48 V AC 50/60 Hz coil - LC1D115E7
Range TeSys
Related Categories