SCHNEIDER
TeSys LC1D - contacteur - 3P - AC-3 440V - 150A - bobine 380Vca - LC1D150Q7
LC1D150Q7
€440.77 Excl. Tax
€528.92 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys D |
---|---|
Range: | TeSys |
Product name: | TeSys D |
Product or component type: | Contactor |
Device short name: | LC1D |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-4AC-1AC-3 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | |
[Ie] rated operational current: | 200 A (150 A ( |
Motor power kW: | 40 kW at 220...230 V AC 50/60 Hz AC-375 kW at 380...400 V AC 50/60 Hz AC-380 kW at 415...440 V AC 50/60 Hz AC-390 kW at 500 V AC 50/60 Hz AC-3100 kW at 660...690 V AC 50/60 Hz AC-375 kW at 1000 V AC 50/60 Hz AC-322 kW at 400 V AC 50/60 Hz AC-4 |
Motor power hp: | 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors50 hp at 230/240 V AC 50/60 Hz for 3 phases motors100 hp at 460/480 V AC 50/60 Hz for 3 phases motors125 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
Control circuit type: | AC 50/60 Hz |
[Uc] control circuit voltage: | 380 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage: | Conforming to IEC 60947 |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 200 A at |
Irms rated making capacity: | 1660 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity: | 1400 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit250 A 580 A 1200 A 1400 A |
Associated fuse rating: | 250 A gG at 315 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
Average impedance: | 0.6 mOhm at 50 Hz - Ith 200 A for power circuit |
[Ui] rated insulation voltage: | 1000 V for power circuit conforming to IEC 60947-4-1600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications UL |
Electrical durability: | 0.85 Mcycles 150 A AC-3 at Ue 1 Mcycles 200 A AC-1 at Ue |
Power dissipation per pole: | 24 W AC-113.5 W AC-3 |
Protective cover: | With |
Mounting support: | PlateRail |
Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
Product certifications: | DNVCCCCSABVGOSTGLULRINALROS |
Connections - terminals: | Control circuit |
Tightening torque: | Control circuit |
Operating time: | 20...35 ms closing40...75 ms opening |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 8 Mcycles |
Operating rate: | 1200 cyc/h at |
Coil technology: | Built-in bidirectional peak limiting diode suppressor |
---|---|
Control circuit voltage limits: | 0.3...0.5 Uc drop-out at 55 °C, AC 50/60 Hz0.8...1.15 Uc operational at 55 °C, AC 50/60 Hz |
Inrush power in VA: | 280...350 VA at 20 °C (cos ? 0.9) 60 Hz280...350 VA at 20 °C (cos ? 0.9) 50 Hz |
Hold-in power consumption in VA: | 2...18 VA at 20 °C (cos ? 0.9) 60 Hz2...18 VA at 20 °C (cos ? 0.9) 50 Hz |
Heat dissipation: | 3...4.5 W at 50/60 Hz |
Auxiliary contacts type: | Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact) |
Insulation resistance: | > 10 MOhm for signalling circuit |
In short
Reference LC1D150Q7
Product Name TeSys LC1D - contacteur - 3P - AC-3 440V - 150A - bobine 380Vca - LC1D150Q7
Range TeSys
Related Categories