Technical informations
Range of product: TeSys D
Range: TeSys
Product name: TeSys D
Product or component type: Contactor
Device short name: LC1D
Contactor application: Motor controlResistive load
Utilisation category: AC-1AC-4AC-3
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage:
[Ie] rated operational current: 18 A (32 A (
Motor power kW: 10 kW at 500 V AC 50/60 Hz AC-310 kW at 660...690 V AC 50/60 Hz AC-34 kW at 220...230 V AC 50/60 Hz AC-37.5 kW at 380...400 V AC 50/60 Hz AC-39 kW at 415...440 V AC 50/60 Hz AC-34 kW at 400 V AC 50/60 Hz AC-4
Motor power hp: 1 hp at 115 V AC 50/60 Hz for 1 phase motors3 hp at 230/240 V AC 50/60 Hz for 1 phase motors5 hp at 200/208 V AC 50/60 Hz for 3 phases motors5 hp at 230/240 V AC 50/60 Hz for 3 phases motors10 hp at 460/480 V AC 50/60 Hz for 3 phases motors15 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Control circuit type: AC 50/60 Hz
[Uc] control circuit voltage: 240 V AC 50/60 Hz
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 32 A at 10 A at
Irms rated making capacity: 300 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity: 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 145 A 240 A 40 A 84 A 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit
Associated fuse rating: 35 A gG at 50 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance: 2.5 mOhm at 50 Hz - Ith 32 A for power circuit
[Ui] rated insulation voltage: 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications UL
Electrical durability: 1.65 Mcycles 18 A AC-3 at Ue 1 Mcycles 32 A AC-1 at Ue
Power dissipation per pole: 0.8 W AC-32.5 W AC-1
Protective cover: With
Mounting support: PlateRail
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
Product certifications: ULGOSTCSADNVCCCLROSGLBVRINA
Connections - terminals: Control circuit
Tightening torque: Power circuit
Operating time: 4...19 ms opening12...22 ms closing
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 15 Mcycles
Operating rate: 3600 cyc/h at
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz0.8...1.1 Uc operational at 60 °C, AC 50 Hz0.85...1.1 Uc operational at 60 °C, AC 60 Hz
Inrush power in VA: 70 VA at 20 °C (cos ? 0.75) 60 Hz70 VA at 20 °C (cos ? 0.75) 50 Hz
Hold-in power consumption in VA: 7.5 VA at 20 °C (cos ? 0.3) 60 Hz7 VA at 20 °C (cos ? 0.3) 50 Hz
Heat dissipation: 2...3 W at 50/60 Hz
Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Non-overlap time: 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact
Insulation resistance: > 10 MOhm for signalling circuit
Motor power range AC-3: 7...11 kW 380...440 V 3 phases7...11 kW 480...500 V 3 phases4...6 kW 200...240 V 3 phases1.1...2 kW 100...120 V 3 phases7...11 kW 525...690 V 3 phases
Motor starter type: Direct on-line contactor
In short
Reference LC1D18U7
Product Name TeSys LC1D - contacteur - 3P - AC-3 440V - 18A - bobine 240Vca  - LC1D18U7
Range TeSys