Technical informations
Range of product: | TeSys DTeSys Deca |
---|---|
Range: | TeSysTeSys Deca |
Product name: | TeSys DTeSys Deca |
Product or component type: | Contactor |
Device short name: | LC1D |
Contactor application: | Resistive load |
Utilisation category: | AC-1 |
Poles description: | 4P |
Pole contact composition: | 2 NO + 2 NC |
[Ue] rated operational voltage: | Power circuit: Power circuit: |
[Ie] rated operational current: | 40 A (at |
Control circuit type: | AC at 50/60 Hz |
[Uc] control circuit voltage: | 400 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 10 A (at 60 °C) for signalling circuit40 A (at 60 °C) for power circuit |
Irms rated making capacity: | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1450 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity: | 450 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 240 A 40 °C - 10 s for power circuit380 A 40 °C - 1 s for power circuit50 A 40 °C - 10 min for power circuit120 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
Associated fuse rating: | 10 A gG for signalling circuit conforming to IEC 60947-5-163 A gG at 40 A gG at |
Average impedance: | 2 mOhm - Ith 40 A 50 Hz for power circuit |
[Ui] rated insulation voltage: | Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified |
Electrical durability: | 1.4 Mcycles 40 A AC-1 at Ue |
Power dissipation per pole: | 3.2 W AC-1 |
Protective cover: | With |
Mounting support: | PlateRail |
Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508IEC 60335-1 |
Product certifications: | CCCBVGLGOSTCSAULDNVLROS (Lloyds register of shipping)RINAUKCA |
Connections - terminals: | Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: connector 1 cable(s) 2.5...10 mm²flexible without cable endPower circuit: connector 2 cable(s) 2.5...10 mm²flexible without cable endPower circuit: connector 1 cable(s) 2.5...10 mm²flexible with cable endPower circuit: connector 2 cable(s) 2.5...10 mm²flexible with cable endPower circuit: connector 1 cable(s) 2.5...16 mm²solid without cable endPower circuit: connector 2 cable(s) 2.5...16 mm²solid without cable end |
Tightening torque: | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 1.8 N.m - on connector - with screwdriver flat Ø 6 mmPower circuit: 1.8 N.m - on connector - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Operating time: | 12...22 ms closing4...19 ms opening |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 15 Mcycles |
Maximum operating rate: | 3600 cyc/h 60 °C |
Coil technology: | Without built-in suppressor module |
---|---|
Control circuit voltage limits: | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
Inrush power in VA: | 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA: | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation: | 2...3 W at 50/60 Hz |
Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact |
Insulation resistance: | > 10 MOhm for signalling circuit |
Contact compatibility: | M6 |
Compatibility code: | LC1D |
In short
Reference LC1D258V7
Product Name TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 40 A - 400 V AC coil - LC1D258V7
Range TeSys
Related Categories