SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 230 V AC 50/60 Hz coil - LC1D40A3P7
LC1D40A3P7
€92.56 Excl. Tax
€111.07 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSysTeSys Deca |
---|---|
Range of product: | TeSys Deca |
Product or component type: | Contactor |
Device short name: | LC1D |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-4AC-1AC-3AC-3e |
Poles description: | 3P |
[Ue] rated operational voltage: | Power circuit: Power circuit: |
[Ie] rated operational current: | 60 A (at 40 A (at 40 A (at |
[Uc] control circuit voltage: | 230 V AC 50/60 Hz |
Motor power kW: | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)11 kW at 220...230 V AC 50/60 Hz (AC-3)22 kW at 415...440 V AC 50/60 Hz (AC-3)22 kW at 500 V AC 50/60 Hz (AC-3)30 kW at 660...690 V AC 50/60 Hz (AC-3)9 kW at 400 V AC 50/60 Hz (AC-4)18.5 kW at 380...400 V AC 50/60 Hz (AC-3e)11 kW at 220...230 V AC 50/60 Hz (AC-3e)22 kW at 415...440 V AC 50/60 Hz (AC-3e)22 kW at 500 V AC 50/60 Hz (AC-3e)30 kW at 660...690 V AC 50/60 Hz (AC-3e) |
---|---|
Motor power hp: | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors10 hp at 230/240 V AC 50/60 Hz for 3 phases motors30 hp at 575/600 V AC 50/60 Hz for 3 phases motors10 hp at 200/208 V AC 50/60 Hz for 3 phases motors3 hp at 115 V AC 50/60 Hz for 1 phase motors30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
Compatibility code: | LC1D |
Pole contact composition: | 3 NO |
Protective cover: | With |
[Ith] conventional free air thermal current: | 10 A (at 60 °C) for signalling circuit60 A (at 60 °C) for power circuit |
Irms rated making capacity: | 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1800 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity: | 800 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 320 A 40 °C - 10 s for power circuit720 A 40 °C - 1 s for power circuit72 A 40 °C - 10 min for power circuit165 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
Associated fuse rating: | 10 A gG for signalling circuit conforming to IEC 60947-5-180 A gG at 80 A gG at |
Average impedance: | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
Power dissipation per pole: | 2.4 W AC-35.4 W AC-12.4 W AC-3e |
[Ui] rated insulation voltage: | Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedPower circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category: | III |
Pollution degree: | 3 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 6 Mcycles |
Electrical durability: | 1.4 Mcycles 60 A AC-1 at Ue 1.5 Mcycles 40 A AC-3 at Ue 1.5 Mcycles 40 A AC-3e at Ue |
Control circuit type: | AC at 50/60 Hz |
Coil technology: | Without built-in suppressor module |
Control circuit voltage limits: | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
Inrush power in VA: | 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA: | 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation: | 4...5 W at 50/60 Hz |
Operating time: | 4...19 ms opening12...26 ms closing |
Maximum operating rate: | 3600 cyc/h 60 °C |
Connections - terminals: | Control circuit: spring terminals 1 0.75...2.5 mm² - cable stiffness: flexible without cable endControl circuit: spring terminals 2 0.75...2.5 mm² - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: flexible without cable endPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: flexible with cable endPower circuit: EverLink BTR screw connectors 1 1...35 mm² - cable stiffness: solid without cable endPower circuit: EverLink BTR screw connectors 2 1...25 mm² - cable stiffness: solid without cable end |
Tightening torque: | Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on EverLink BTR screw connectors - cable 0.75...25 mm² hexagonal screw head 4 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Auxiliary contact composition: | 1 NO + 1 NC |
Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching voltage: | 17 V for signalling circuit |
Minimum switching current: | 5 mA for signalling circuit |
Insulation resistance: | > 10 MOhm for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact |
Mounting support: | RailPlate |
Contact compatibility: | M2 |
In short
Reference LC1D40A3P7
Product Name TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 230 V AC 50/60 Hz coil - LC1D40A3P7