Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 48 V AC 50/60 Hz coil - LC1D80E7

LC1D80E7

€180.84 Excl. Tax
€217.01 Inc. Tax
available In stock more than 25 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys D
Range: TeSys
Product name: TeSys D
Product or component type: Contactor
Device short name: LC1D
Contactor application: Motor controlResistive load
Utilisation category: AC-3AC-1AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: Power circuit:
[Ie] rated operational current: 125 A (at 80 A (at
Motor power kW: 22 kW at 220...230 V AC 50/60 Hz (AC-3)37 kW at 380...400 V AC 50/60 Hz (AC-3)45 kW at 415...440 V AC 50/60 Hz (AC-3)55 kW at 500 V AC 50/60 Hz (AC-3)45 kW at 660...690 V AC 50/60 Hz (AC-3)45 kW at 1000 V AC 50/60 Hz (AC-3)15 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp: 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors30 hp at 200/208 V AC 50/60 Hz for 3 phases motors30 hp at 230/240 V AC 50/60 Hz for 3 phases motors60 hp at 460/480 V AC 50/60 Hz for 3 phases motors60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 48 V AC 50/60 Hz
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuit
Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-11100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at 160 A gG at
Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified
Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue 1.5 Mcycles 80 A AC-3 at Ue
Power dissipation per pole: 5.1 W AC-312.5 W AC-1
Protective cover: With
Mounting support: PlateRail
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
Product certifications: CSABVULGOSTRINACCCGLLROS (Lloyds register of shipping)DNV
Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible without cable endPower circuit: connector 2 cable(s) 4...25 mm²flexible without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible with cable endPower circuit: connector 2 cable(s) 4...16 mm²flexible with cable endPower circuit: connector 1 cable(s) 4...50 mm²solid without cable endPower circuit: connector 2 cable(s) 4...25 mm²solid without cable end
Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mmPower circuit: 12 N.m - on connector hexagonal screw head 4 mm
Operating time: 20...35 ms closing6...20 ms opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 4 Mcycles
Maximum operating rate: 3600 cyc/h 60 °C
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.85...1.1 Uc (-40...55 °C):operational AC 60 Hz0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...55 °C):operational AC 50 Hz1...1.1 Uc (55...70 °C):operational AC 50/60 Hz
Inrush power in VA: 245 VA 60 Hz cos phi 0.75 (at 20 °C)245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA: 26 VA 60 Hz cos phi 0.3 (at 20 °C)26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation: 6...10 W at 50/60 Hz
Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
Insulation resistance: > 10 MOhm for signalling circuit
Contact compatibility: M11
Compatibility code: LC1D
Power range: 55...100 kW at 480...500 V 3 phases15...25 kW at 200...240 V 3 phases30...50 kW at 380...440 V 3 phases30...50 kW at 480...500 V 3 phases
Motor starter type: Direct on-line contactor
Contactor coil voltage: 48 V AC standard
In short
Reference LC1D80E7
Product Name TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A - 48 V AC 50/60 Hz coil - LC1D80E7
Range TeSys
Related Categories