SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 95 A - 440 V AC 50/60 Hz coil - LC1D95R7
LC1D95R7
€423.54 Excl. Tax
€508.25 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys D |
---|---|
Range: | TeSys |
Product name: | TeSys D |
Product or component type: | Contactor |
Device short name: | LC1D |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-3AC-1AC-4 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | Power circuit: 1000 V AC 25...400 Hz |
[Ie] rated operational current: | 95 A (at 125 A (at |
Motor power kW: | 25 kW at 220...230 V AC 50 Hz (AC-3)45 kW at 380...400 V AC 50 Hz (AC-3)45 kW at 415...440 V AC 50 Hz (AC-3)55 kW at 500 V AC 50 Hz (AC-3)45 kW at 660...690 V AC 50 Hz (AC-3)45 kW at 1000 V AC 50 Hz (AC-3) |
Motor power hp: | 7.5 hp at 120 V AC 60 Hz for 1 phase motors15 hp at 230/240 V AC 60 Hz for 1 phase motors30 hp at 200/208 V AC 60 Hz for 3 phases motors30 hp at 230/240 V AC 60 Hz for 3 phases motors60 hp at 460/480 V AC 60 Hz for 3 phases motors60 hp at 575/600 V AC 60 Hz for 3 phases motors |
Control circuit type: | AC at 50/60 Hz |
[Uc] control circuit voltage: | 440 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947 |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 10 A (at 60 °C) for signalling circuit125 A (at 60 °C) for power circuit |
Irms rated making capacity: | 1100 A at 440 V AC for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity: | 1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 1100 A 40 °C - 1 s for power circuit800 A 40 °C - 10 s for power circuit400 A 40 °C - 1 min for power circuit135 A 40 °C - 10 min for power circuit140 A - 100 ms for signalling circuit120 A - 500 ms for signalling circuit100 A - 1 s for signalling circuit |
Associated fuse rating: | 10 A gG for signalling circuit conforming to IEC 60947-5-1200 A gG at 160 A gG at |
Average impedance: | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
[Ui] rated insulation voltage: | Power circuit: 1000 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified |
Electrical durability: | 1.2 Mcycles 95 A AC-31.3 Mcycles 125 A AC-1 |
Power dissipation per pole: | 12.5 W AC-17.2 W AC-3 |
Protective cover: | With |
Mounting support: | PlateRail |
Standards: | EN/IEC 60947-1EN/IEC 60947-4-1EN/IEC 60947-5-1UL 60947-4-1UL 60947-5-1CSA C22.2 No 60947-4-1CSA C22.2 No 60947-5-1GB/T 14048.4 |
Product certifications: | IECEE CB SchemeULCSACCCEACLROS (Lloyds register of shipping)RINABVDNV-GL |
Connections - terminals: | Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible without cable endPower circuit: connector 2 cable(s) 4...25 mm²flexible without cable endPower circuit: connector 1 cable(s) 4...50 mm²flexible with cable endPower circuit: connector 2 cable(s) 4...16 mm²flexible with cable endPower circuit: connector 1 cable(s) 4...50 mm²solid without cable endPower circuit: connector 2 cable(s) 4...25 mm²solid without cable end |
Tightening torque: | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mmPower circuit: 12 N.m - on connector hexagonal screw head 4 mm |
Operating time: | 20...35 ms closing6...20 ms opening |
Safety reliability level: | B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 4 Mcycles |
Maximum operating rate: | 3600 cyc/h 60 °C |
Coil technology: | Without built-in suppressor module |
---|---|
Control circuit voltage limits: | 0.8...1.1 Uc (-40...55 °C):operational AC 50 Hz0.85...1.1 Uc (-40...55 °C):operational AC 60 Hz0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz1...1.1 Uc (55...70 °C):operational AC 50/60 Hz |
Inrush power in VA: | 245 VA 60 Hz cos phi 0.75 (at 20 °C)245 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA: | 26 VA 60 Hz cos phi 0.3 (at 20 °C)26 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation: | 6...10 W at 50/60 Hz |
Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact |
Insulation resistance: | > 10 MOhm for signalling circuit |
Contact compatibility: | M11 |
Compatibility code: | LC1D |
In short
Reference LC1D95R7
Product Name TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 95 A - 440 V AC 50/60 Hz coil - LC1D95R7
Range TeSys
Related Categories