SCHNEIDER

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 185A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC - LC1F185

LC1F185

€528.42 Excl. Tax
€634.10 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys F
Range: TeSys
Product name: TeSys F
Product or component type: Contactor
Device short name: LC1F
Contactor application: Resistive loadMotor control
Utilisation category: AC-3AC-4AC-1
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage:
[Ie] rated operational current: 275 A (at 185 A (at
Motor power kW: 100 kW at 415 V AC 50/60 Hz (AC-3)100 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)90 kW at 380...400 V AC 50/60 Hz (AC-3)55 kW at 220...240 V AC 50/60 Hz (AC-3)110 kW at 660...690 V AC 50/60 Hz (AC-3)33 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage: 24...575 V AC 40...400 Hz with LX9 coil24...460 V DC with LX4 coil100...250 V AC 50/60 Hz with LXE coil100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 275 A (at 40 °C)
Irms rated making capacity: 1850 A conforming to IEC 60947-4-1
Rated breaking capacity: 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current: 1500 A 40 °C - 10 s920 A 40 °C - 30 s740 A 40 °C - 1 min500 A 40 °C - 3 min400 A 40 °C - 10 min
Associated fuse rating: 200 A aM at 315 A gG at
Average impedance: 0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
Control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coilDrop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.15...0.2 Uc DC with LX4 coilOperational: 85...275 V AC 50/60 Hz with LXE coilDrop-out: 0...60 V AC 50/60 Hz with LXE coilOperational: 85...418 V DC with LXE coilDrop-out: 0...45 V DC with LXE coil
Power dissipation per pole: 25 W AC-112 W AC-3
Heat dissipation: 8...9.8 W2.2...2.5 W
Operating time: 35 ms closing for with LX9 coil130 ms opening for with LX9 coil30...40 ms closing for with LX4 coil30...50 ms opening for with LX4 coil40...80 ms closing for with LXE coil6...54 ms opening for with LXE coil
Mounting support: Plate
Standards: IEC 60947-4-1EN 60947-1JIS C8201-4-1EN 60947-4-1IEC 60947-1
Product certifications: ABSLROS (Lloyds register of shipping)RINACSACBULBVRMRoSDNVUKCA
Connections - terminals: Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 150 mm²Power circuit: connector 1 cable(s) 150 mm²Power circuit: bolted connectionControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²solid without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²Control circuit: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 1.0 cable(s) 0.25...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²solid without cable end
Tightening torque: Power circuit: 18 N.mControl circuit: 1.2 N.mControl circuit: 0.6 N.m
Mechanical durability: 10 Mcycles
Inrush power in VA: 950...1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil737...902 VA (at 20 °C)with LX4 coil280...310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil270...320 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA: 8.9...10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil4.13...5.07 VA (at 20 °C)with LX4 coil4.5...7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil2.5...4.0 VA (at 20 °C)with LXE coil
Compatibility code: LC1F