SCHNEIDER
TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 185A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC - LC1F185
LC1F185
€528.42 Excl. Tax
€634.10 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys F |
---|---|
Range: | TeSys |
Product name: | TeSys F |
Product or component type: | Contactor |
Device short name: | LC1F |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-3AC-4AC-1 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | |
[Ie] rated operational current: | 275 A (at 185 A (at |
Motor power kW: | 100 kW at 415 V AC 50/60 Hz (AC-3)100 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)90 kW at 380...400 V AC 50/60 Hz (AC-3)55 kW at 220...240 V AC 50/60 Hz (AC-3)110 kW at 660...690 V AC 50/60 Hz (AC-3)33 kW at 400 V AC 50/60 Hz (AC-4) |
[Uc] control circuit voltage: | 24...575 V AC 40...400 Hz with LX9 coil24...460 V DC with LX4 coil100...250 V AC 50/60 Hz with LXE coil100...380 V DC with LXE coil |
---|---|
[Uimp] rated impulse withstand voltage: | 8 kV |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 275 A (at 40 °C) |
Irms rated making capacity: | 1850 A conforming to IEC 60947-4-1 |
Rated breaking capacity: | 1480 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current: | 1500 A 40 °C - 10 s920 A 40 °C - 30 s740 A 40 °C - 1 min500 A 40 °C - 3 min400 A 40 °C - 10 min |
Associated fuse rating: | 200 A aM at 315 A gG at |
Average impedance: | 0.33 mOhm - Ith 275 A 50 Hz |
[Ui] rated insulation voltage: | 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C |
Control circuit voltage limits: | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coilDrop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.15...0.2 Uc DC with LX4 coilOperational: 85...275 V AC 50/60 Hz with LXE coilDrop-out: 0...60 V AC 50/60 Hz with LXE coilOperational: 85...418 V DC with LXE coilDrop-out: 0...45 V DC with LXE coil |
Power dissipation per pole: | 25 W AC-112 W AC-3 |
Heat dissipation: | 8...9.8 W2.2...2.5 W |
Operating time: | 35 ms closing for with LX9 coil130 ms opening for with LX9 coil30...40 ms closing for with LX4 coil30...50 ms opening for with LX4 coil40...80 ms closing for with LXE coil6...54 ms opening for with LXE coil |
Mounting support: | Plate |
Standards: | IEC 60947-4-1EN 60947-1JIS C8201-4-1EN 60947-4-1IEC 60947-1 |
Product certifications: | ABSLROS (Lloyds register of shipping)RINACSACBULBVRMRoSDNVUKCA |
Connections - terminals: | Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 150 mm²Power circuit: connector 1 cable(s) 150 mm²Power circuit: bolted connectionControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²solid without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²Control circuit: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 1.0 cable(s) 0.25...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²solid without cable end |
Tightening torque: | Power circuit: 18 N.mControl circuit: 1.2 N.mControl circuit: 0.6 N.m |
Mechanical durability: | 10 Mcycles |
Inrush power in VA: | 950...1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil737...902 VA (at 20 °C)with LX4 coil280...310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil270...320 VA (at 20 °C)with LXE coil |
Hold-in power consumption in VA: | 8.9...10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil4.13...5.07 VA (at 20 °C)with LX4 coil4.5...7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil2.5...4.0 VA (at 20 °C)with LXE coil |
Compatibility code: | LC1F |
In short
Reference LC1F185
Product Name TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 185A with coil LX9 - 24...600V AC 40/400Hz, LX4 - 24...460V DC, LXE - 100...250V AC 50/60Hz or 100…380V DC - LC1F185
Range TeSys