SCHNEIDER
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 185 A - coil 230 V AC - LC1F185P7
LC1F185P7
Obsolete product, here is the proposed substitution for the reference LC1F185P7 : LC1G185KUEN
Technical informations
Range of product: | TeSys F |
---|---|
Range: | TeSys |
Product name: | TeSys F |
Product or component type: | Contactor |
Device short name: | LC1F |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-4AC-3AC-1 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | |
[Ie] rated operational current: | 275 A (at 185 A (at |
Motor power kW: | 90 kW at 380...400 V AC 50/60 Hz (AC-3)100 kW at 415 V AC 50/60 Hz (AC-3)100 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)110 kW at 660...690 V AC 50/60 Hz (AC-3)55 kW at 220...230 V AC 50/60 Hz (AC-3)33 kW at 400 V AC 50/60 Hz (AC-4) |
Control circuit type: | AC at 40...400 Hz |
[Uc] control circuit voltage: | 230 V AC 40...400 Hz |
[Uimp] rated impulse withstand voltage: | 8 kV |
---|---|
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 275 A (at 40 °C) |
Rated breaking capacity: | 1480 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current: | 1500 A 40 °C - 10 s920 A 40 °C - 30 s740 A 40 °C - 1 min500 A 40 °C - 3 min400 A 40 °C - 10 min |
Associated fuse rating: | 200 A aM at 315 A gG at |
Average impedance: | 0.33 mOhm - Ith 275 A 50 Hz |
[Ui] rated insulation voltage: | 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C |
Power dissipation per pole: | 12 W AC-325 W AC-1 |
Mounting support: | Plate |
Standards: | EN 60947-1IEC 60947-4-1IEC 60947-1EN 60947-4-1JIS C8201-4-1 |
Product certifications: | CSACBLROS (Lloyds register of shipping)DNVULBVABSRMRoSRINAUKCA |
Connections - terminals: | Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 150 mm²Power circuit: connector 1 cable(s) 150 mm²Power circuit: bolted connection |
Tightening torque: | Control circuit: 1.2 N.mPower circuit: 18 N.m |
Control circuit voltage limits: | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C) |
Inrush power in VA: | 1070 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA: | 9.9 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
Heat dissipation: | 8...9.8 W |
Operating time: | 35 ms closing (at Uc) 130 ms opening (at Uc) |
Mechanical durability: | 10 Mcycles |
Maximum operating rate: | 2400 cyc/h 55 °C |
Compatibility code: | LC1F |
Power range: | 30...50 kW at 200...240 V 3 phases55...100 kW at 200...240 V 3 phases55...100 kW at 380...440 V 3 phases55...100 kW at 480...500 V 3 phases110...220 kW at 480...500 V 3 phases |
Motor starter type: | Direct on-line contactor |
Contactor coil voltage: | 230 V AC standard |
In short
Reference LC1F185P7
Product Name TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 185 A - coil 230 V AC - LC1F185P7
Range TeSys
Related Categories