Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
100 products at 10% off until 18 November! Find out more
SCHNEIDER

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 185 A - coil 240 V AC - LC1F185U7

LC1F185U7

Obsolete product, here is the proposed substitution for the reference LC1F185U7 : LC1G185KUEN
Technical informations
Range: TeSys
Range of product: TeSys F
Product or component type: Contactor
Device short name: LC1F
Contactor application: Resistive loadMotor control
Utilisation category: AC-4AC-1AC-3
Poles description: 3P
[Ue] rated operational voltage:
[Uc] control circuit voltage: 240 V AC 40...400 Hz
[Ie] rated operational current: 275 A (at 185 A (at
[Uimp] rated impulse withstand voltage: 8 kV
[Ith] conventional free air thermal current: 275 A (at 40 °C)
Rated breaking capacity: 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current: 1500 A 40 °C - 10 s920 A 40 °C - 30 s740 A 40 °C - 1 min500 A 40 °C - 3 min400 A 40 °C - 10 min
Associated fuse rating: 200 A aM at 315 A gG at
Average impedance: 0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
Power dissipation per pole: 12 W AC-325 W AC-1
Overvoltage category: III
Pole contact composition: 3 NO
Motor power kW: 90 kW at 380...400 V AC 50/60 Hz (AC-3)100 kW at 415 V AC 50/60 Hz (AC-3)100 kW at 440 V AC 50/60 Hz (AC-3)110 kW at 500 V AC 50/60 Hz (AC-3)110 kW at 660...690 V AC 50/60 Hz (AC-3)55 kW at 220...230 V AC 50/60 Hz (AC-3)33 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits: Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
Mechanical durability: 10 Mcycles
Inrush power in VA: 1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA: 9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum operating rate: 2400 cyc/h 55 °C
Operating time: 35 ms closing (at Uc) 130 ms opening (at Uc)
Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mmPower circuit: lugs-ring terminals 1 cable(s) 150 mm²Power circuit: connector 1 cable(s) 150 mm²Power circuit: bolted connection
Tightening torque: Control circuit: 1.2 N.mPower circuit: 18 N.m
Mounting support: Plate
Heat dissipation: 8...9.8 W
Power range: 30...50 kW at 200...240 V 3 phases55...100 kW at 200...240 V 3 phases55...100 kW at 380...440 V 3 phases55...100 kW at 480...500 V 3 phases110...220 kW at 480...500 V 3 phases
Motor starter type: Direct on-line contactor
Contactor coil voltage: 240 V AC standard
Standards: IEC 60947-1JIS C8201-4-1EN 60947-1IEC 60947-4-1EN 60947-4-1
Product certifications: LROS (Lloyds register of shipping)ULCSABVCBDNVRMRoSRINAABSUKCA
Compatibility code: LC1F
Control circuit type: AC at 40...400 Hz
In short
Reference LC1F185U7
Product Name TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 185 A - coil 240 V AC - LC1F185U7
Range TeSys