TeSys LC1F - contacteur - 3P - AC-3 440V - 225A - bobine 110Vca  - LC1F225F7

LC1F225F7

Obsolete product, here is the proposed substitution for the reference LC1F225F7 : LC1G225EHEN
Technical informations
Range of product: TeSys F
Range: TeSys
Product name: TeSys F
Product or component type: Contactor
Device short name: LC1F
Contactor application: Motor controlResistive load
Motor power kW: 100 kW at 1000 V AC 50/60 Hz AC-3110 kW at 380...400 V AC 50/60 Hz AC-3110 kW at 415 V AC 50/60 Hz AC-3110 kW at 440 V AC 50/60 Hz AC-3129 kW at 500 V AC 50/60 Hz AC-3129 kW at 660?690 V AC 50/60 Hz AC-363 kW at 220...230 V AC 50/60 Hz AC-340 kW at 400 V AC 50/60 Hz AC-4
Control circuit type: AC 40...400 Hz
[Uc] control circuit voltage: 110 V AC 40...400 Hz
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 315 A at
Rated breaking capacity: 1800 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current: 1800 A 1000 A 850 A 560 A 440 A
Associated fuse rating: 315 A gG at 250 A aM at
Average impedance: 0.32 mOhm at 50 Hz - Ith 315 A
[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
Power dissipation per pole: 16 W AC-332 W AC-1
Mounting support: Plate
Standards: EN 60947-1EN 60947-4-1IEC 60947-1IEC 60947-4-1JEM 1038
Product certifications: BVCCCCSADNVGLRMRoSULLROS
Connections - terminals: Control circuit
Tightening torque: Power circuit
Operating time: 20...35 ms closing7...15 ms opening
Mechanical durability: 10 Mcycles
Operating rate: 2400 cyc/h at
Utilisation category: AC-1AC-3AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage:
[Ie] rated operational current: 315 A (225 A (
Control circuit voltage limits: 0.35...0.55 Uc at 55 °C drop-out 50/60 Hz0.85...1.1 Uc at 55 °C operational 50/60 Hz
Inrush power in VA: 805 VA at 20 °C (cos ? 0.3) 50 Hz970 VA at 20 °C (cos ? 0.3) 60 Hz
Hold-in power consumption in VA: 55 VA at 20 °C (cos ? 0.3) 50 Hz66 VA at 20 °C (cos ? 0.3) 60 Hz
Heat dissipation: 18...24 W
Motor power range AC-3: 110...220 kW 380...440 V 3 phases55...100 kW 200...240 V 3 phases110...220 kW 480...500 V 3 phases
Motor starter type: Direct on-line contactor
Contactor coil voltage: 110 V AC
In short
Reference LC1F225F7
Product Name TeSys LC1F - contacteur - 3P - AC-3 440V - 225A - bobine 110Vca  - LC1F225F7
Range TeSys
Related Categories