Technical informations
Range of product: | TeSys F |
---|---|
Range: | TeSys |
Product name: | TeSys F |
Product or component type: | Contactor |
Device short name: | LC1F |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-1AC-3AC-4 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | |
[Ie] rated operational current: | 500 A (at 400 A (at |
Motor power kW: | 75 kW at 400 V AC 50/60 Hz (AC-4)200 kW at 380...400 V AC 50/60 Hz (AC-3)220 kW at 415 V AC 50/60 Hz (AC-3)250 kW at 440 V AC 50/60 Hz (AC-3)257 kW at 500 V AC 50/60 Hz (AC-3)280 kW at 660...690 V AC 50/60 Hz (AC-3)185 kW at 1000 V AC 50/60 Hz (AC-3)110 kW at 220...230 V AC 50/60 Hz (AC-3) |
Control circuit type: | AC at 40...400 Hz |
[Uc] control circuit voltage: | 230 V AC 40...400 Hz |
[Uimp] rated impulse withstand voltage: | 8 kV |
---|---|
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 500 A (at 40 °C) |
Rated breaking capacity: | 3200 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current: | 3600 A 40 °C - 10 s2400 A 40 °C - 30 s1700 A 40 °C - 1 min1200 A 40 °C - 3 min1000 A 40 °C - 10 min |
Associated fuse rating: | 400 A aM at 500 A gG at |
Average impedance: | 0.26 mOhm - Ith 500 A 50 Hz |
[Ui] rated insulation voltage: | 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C |
Power dissipation per pole: | 65 W AC-142 W AC-3 |
Mounting support: | Plate |
Standards: | EN 60947-1EN 60947-4-1IEC 60947-1IEC 60947-4-1JIS C8201-4-1 |
Product certifications: | ABSCSAULBVDNVRMRoSLROS (Lloyds register of shipping)CBRINAUKCA |
Connections - terminals: | Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mmPower circuit: lugs-ring terminals 2 cable(s) 150 mm²Power circuit: bolted connection |
Tightening torque: | Control circuit: 1.2 N.mPower circuit: 35 N.m |
Control circuit voltage limits: | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) |
Inrush power in VA: | 1075 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
Hold-in power consumption in VA: | 15 VA 40...400 Hz cos phi 0.9 (at 20 °C) |
Heat dissipation: | 14 W |
Operating time: | 40...65 ms closing100...170 ms opening |
Mechanical durability: | 10 Mcycles |
Maximum operating rate: | 2400 cyc/h 55 °C |
Compatibility code: | LC1F |
Power range: | 110...220 kW at 480...500 V 3 phases110...220 kW at 380...440 V 3 phases110...220 kW at 200...240 V 3 phases250...500 kW at 480...500 V 3 phases |
Motor starter type: | Direct on-line contactor |
Contactor coil voltage: | 230 V AC standard |