Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 500A, standard version, 100…250V wide band AC/DC coil - LC1G500KUEN

LC1G500KUEN

€1,429.72 Excl. Tax
€1,715.66 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range: TeSys
Range of product: TeSys Giga
Product or component type: Contactor
Device short name: LC1G
Contactor application: Power switchingMotor control
Utilisation category: AC-1AC-3AC-3eAC-4AC-5aAC-5bAC-6aAC-6bAC-8aAC-8bDC-1DC-3DC-5
Poles description: 3P
[Ue] rated operational voltage:
[Ie] rated operational current: 700 A (at 500 A (at
[Uc] control circuit voltage: 100...250 V AC 50/60 Hz100...250 V DC
Control circuit voltage limits: Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at
Number of modules per PLC per PC: 0
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 700 A (at 40 °C)
Rated breaking capacity: 4600 A at 440 V
[Icw] rated short-time withstand current: 4.0 kA - 10 s2.8 kA - 30 s2.2 kA - 1 min1.5 kA - 3 min1.2 kA - 10 min
Associated fuse rating: 500 A aM at 400 A aM at 800 A gG at
Average impedance: 0.00008 Ohm
[Ui] rated insulation voltage: 1000 V
Power dissipation per pole: 40 W AC-1 - Ith 700 A20 W AC-3 - Ith 500 A
Compatibility code: LC1G
Pole contact composition: 3 NO
Auxiliary contact composition: 1 NO + 1 NC
Motor power kW: 147 kW at 230 V AC 50/60 Hz (AC-3e)250 kW at 400 V AC 50/60 Hz (AC-3e)250 kW at 415 V AC 50/60 Hz (AC-3e)280 kW at 440 V AC 50/60 Hz (AC-3e)315 kW at 500 V AC 50/60 Hz (AC-3e)355 kW at 690 V AC 50/60 Hz (AC-3e)335 kW at 1000 V AC 50/60 Hz (AC-3e)160 kW at 230 V AC 50/60 Hz (AC-3)250 kW at 400 V AC 50/60 Hz (AC-3)250 kW at 415 V AC 50/60 Hz (AC-3)315 kW at 440 V AC 50/60 Hz (AC-3)355 kW at 500 V AC 50/60 Hz (AC-3)355 kW at 690 V AC 50/60 Hz (AC-3)335 kW at 1000 V AC 50/60 Hz (AC-3)150 kW at 230 V AC 50/60 Hz (AC-4)250 kW at 400 V AC 50/60 Hz (AC-4)250 kW at 415 V AC 50/60 Hz (AC-4)295 kW at 440 V AC 50/60 Hz (AC-4)295 kW at 500 V AC 50/60 Hz (AC-4)355 kW at 690 V AC 50/60 Hz (AC-4)280 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp: 150 hp at 200/208 V 60 Hz200 hp at 230/240 V 60 Hz400 hp at 460/480 V 60 Hz450 hp at 575/600 V 60 Hz
Irms rated making capacity: 5090 A at 440 V
Control circuit voltage limits: Operational: 0.8...1.1 Uc AC/DC (at 60 °C)Drop-out: 0.1...0.45 Uc AC/DC (at 60 °C)
Coil technology: Built-in bidirectional peak limiting
Electrical durability: 300 cycles AC-1 at Ue 400 V500 cycles AC-3 at Ue 400 V500 cycles AC-3e at Ue 400 V150 cycles AC-4 at Ue 400 V
Mechanical durability: 8 Mcycles
Inrush power in VA: 750 VA
Inrush power in W: 660 W
Hold-in power consumption in VA: 15.5 VA
Hold-in power consumption in W: 9.3 W
Operating time: 40...70 ms closing15...50 ms opening
Maximum operating rate: 300 cyc/h AC-1500 cyc/h AC-3500 cyc/h AC-3e150 cyc/h AC-4
Connections - terminals: Power circuit: bar 2 - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 185 mm²Power circuit: bolted connectionControl circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5...1.0 mm² with cable endControl circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end
Connection pitch: 45 mm
Mounting support: Plate
Standards: EN/IEC 60947-4-1EN/IEC 60947-5-1UL 60947-4-1CSA C22.2 No 60947-4-1JIS C8201-4-1JIS C8201-5-1
Product certifications: CB SchemeCCCcULusEACCEUKCAEU-RO-MR by DNV-GL
Tightening torque: 35 N.m
Height: 225 mm
Width: 140 mm
Depth: 226 mm
Net weight: 7.5 kg
In short
Reference LC1G500KUEN
Product Name High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 500A, standard version, 100…250V wide band AC/DC coil - LC1G500KUEN
Range TeSys
Related Categories