TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 24 V AC coil - LC1K1201B7
LC1K1201B7
€28.16 Excl. Tax
€33.79 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys K |
---|---|
Range: | TeSys |
Product or component type: | Contactor |
Product name: | TeSys K |
Device short name: | LC1K |
Device application: | Control |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-4AC-3AC-1 |
---|---|
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ie] rated operational current: | 20 A (at 12 A at 16 A (at |
Control circuit type: | AC at 50/60 Hz |
[Uc] control circuit voltage: | 24 V AC 50/60 Hz |
Motor power kW: | 4 kW at 480 V AC 50/60 Hz AC-34 kW at 500...600 V AC 50/60 Hz AC-34 kW at 660...690 V AC 50/60 Hz AC-32.2 kW at 400 V AC 50/60 Hz AC-43 kW at 220...230 V AC 50/60 Hz AC-35.5 kW at 380...415 V AC 50/60 Hz AC-35.5 kW at 440 V AC 50/60 Hz AC-3 |
Auxiliary contact composition: | 1 NC |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit |
Irms rated making capacity: | 110 A AC for signalling circuit conforming to IEC 60947144 A AC for power circuit conforming to NF C 63-110144 A AC for power circuit conforming to IEC 60947 |
Rated breaking capacity: | 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
Associated fuse rating: | 25 A gG at 25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660 |
Average impedance: | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Insulation resistance: | > 10 MOhm for signalling circuit |
Inrush power in VA: | 30 VA (at 20 °C) |
Hold-in power consumption in VA: | 4.5 VA (at 20 °C) |
Heat dissipation: | 1.3 W |
Control circuit voltage limits: | Operational: 0.8...1.15 Uc (at Drop-out: 0.2...0.75 Uc (at |
Maximum operating rate: | 3600 cyc/h |
Auxiliary contacts type: | type instantaneous 1 NC |
Signalling circuit frequency: | |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Operating time: | 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Non overlap distance: | 0.5 mm |
Mechanical robustness: | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Compatibility code: | LC1K |
In short
Reference LC1K1201B7
Product Name TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 24 V AC coil - LC1K1201B7