Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Contacteur inverseur TeSys LC2D 3P AC3 440V 9 A bobine 24 VCC - LC2D09BD

LC2D09BD

€126.45 Excl. Tax
€151.74 Inc. Tax
available In stock more than 100 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys D
Range: TeSys
Product name: TeSys D
Product or component type: Reversing contactor
Device short name: LC2D
Contactor application: Resistive loadMotor control
Utilisation category: AC-3AC-1
Device presentation: Preassembled with reversing power busbar
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage:
[Ie] rated operational current: 25 A (9 A (
Motor power kW: 4 kW at 380...400 V AC 50/60 Hz2.2 kW at 220...230 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz5.5 kW at 660...690 V AC 50/60 Hz4 kW at 415...440 V AC 50/60 Hz
Motor power hp: 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phases motors2 hp at 230/240 V AC 50/60 Hz for 3 phases motors5 hp at 460/480 V AC 50/60 Hz for 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Control circuit type: DC standard
[Uc] control circuit voltage: 24 V DC
Auxiliary contact composition: 1 NO + 1 NC
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 25 A at 10 A at
Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 105 A 210 A 30 A 61 A 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit
Associated fuse rating: 20 A gG at 25 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1
Average impedance: 2.5 mOhm at 50 Hz - Ith 25 A for power circuit
[Ui] rated insulation voltage: 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications UL
Electrical durability: 0.6 Mcycles 25 A AC-1 at Ue 2 Mcycles 9 A AC-3 at Ue
Power dissipation per pole: 0.2 W AC-31.56 W AC-1
Protective cover: With
Interlocking type: Mechanical
Mounting support: RailPlate
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
Product certifications: GLLROSBVCSACCCDNVRINAULGOST
Connections - terminals: Control circuit
Tightening torque: Power circuit
Operating time: 53.55...72.45 ms closing16...24 ms opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 30 Mcycles
Operating rate: 3600 cyc/h at
Coil technology: Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits: 0.1...0.25 Uc drop-out at 60 °C, DC0.7...1.25 Uc operational at 60 °C, DC
Time constant: 28 ms
Inrush power in W: 5.4 W at 20 °C
Hold-in power consumption in W: 5.4 W at 20 °C
Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V Signalling circuit
Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)
Insulation resistance: > 10 MOhm for signalling circuit
Motor power range AC-3: 1.1...2 kW 200...240 V 3 phases2.2...3 kW 380...440 V 3 phases4...6 kW 380...440 V 3 phases4...6 kW 480...500 V 3 phases
Motor starter type: Reversing contactor
Contactor coil voltage: 24 V DC standard
In short
Reference LC2D09BD
Product Name Contacteur inverseur TeSys LC2D 3P AC3 440V 9 A bobine 24 VCC - LC2D09BD
Range TeSys
Related Categories