Contacteur inverseur TeSys LC2D 3P AC3 440V 9 A bobine 24 VCC - LC2D09BD
LC2D09BD
€126.45 Excl. Tax
€151.74 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys D |
---|---|
Range: | TeSys |
Product name: | TeSys D |
Product or component type: | Reversing contactor |
Device short name: | LC2D |
Contactor application: | Resistive loadMotor control |
Utilisation category: | AC-3AC-1 |
Device presentation: | Preassembled with reversing power busbar |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | |
[Ie] rated operational current: | 25 A (9 A ( |
Motor power kW: | 4 kW at 380...400 V AC 50/60 Hz2.2 kW at 220...230 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz5.5 kW at 660...690 V AC 50/60 Hz4 kW at 415...440 V AC 50/60 Hz |
Motor power hp: | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phases motors2 hp at 230/240 V AC 50/60 Hz for 3 phases motors5 hp at 460/480 V AC 50/60 Hz for 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
Control circuit type: | DC standard |
[Uc] control circuit voltage: | 24 V DC |
Auxiliary contact composition: | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 25 A at 10 A at |
Irms rated making capacity: | 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Rated breaking capacity: | 250 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 105 A 210 A 30 A 61 A 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit |
Associated fuse rating: | 20 A gG at 25 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
Average impedance: | 2.5 mOhm at 50 Hz - Ith 25 A for power circuit |
[Ui] rated insulation voltage: | 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications UL |
Electrical durability: | 0.6 Mcycles 25 A AC-1 at Ue 2 Mcycles 9 A AC-3 at Ue |
Power dissipation per pole: | 0.2 W AC-31.56 W AC-1 |
Protective cover: | With |
Interlocking type: | Mechanical |
Mounting support: | RailPlate |
Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
Product certifications: | GLLROSBVCSACCCDNVRINAULGOST |
Connections - terminals: | Control circuit |
Tightening torque: | Power circuit |
Operating time: | 53.55...72.45 ms closing16...24 ms opening |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 30 Mcycles |
Operating rate: | 3600 cyc/h at |
Coil technology: | Built-in bidirectional peak limiting diode suppressor |
---|---|
Control circuit voltage limits: | 0.1...0.25 Uc drop-out at 60 °C, DC0.7...1.25 Uc operational at 60 °C, DC |
Time constant: | 28 ms |
Inrush power in W: | 5.4 W at 20 °C |
Hold-in power consumption in W: | 5.4 W at 20 °C |
Auxiliary contacts type: | Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V Signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact) |
Insulation resistance: | > 10 MOhm for signalling circuit |
Motor power range AC-3: | 1.1...2 kW 200...240 V 3 phases2.2...3 kW 380...440 V 3 phases4...6 kW 380...440 V 3 phases4...6 kW 480...500 V 3 phases |
Motor starter type: | Reversing contactor |
Contactor coil voltage: | 24 V DC standard |
In short
Reference LC2D09BD
Product Name Contacteur inverseur TeSys LC2D 3P AC3 440V 9 A bobine 24 VCC - LC2D09BD
Range TeSys