Technical informations
Range of product: TeSys D
Range: TeSys
Product name: TeSys D
Product or component type: Changeover contactor
Device short name: LC2D
Contactor application: Resistive load
Utilisation category: AC-1
Device presentation: Preassembled with reversing power busbar
Poles description: 4P
Pole contact composition: 4 NO
[Ue] rated operational voltage: Power circuit: Power circuit:
[Ie] rated operational current: 200 A (at
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 230 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
Overvoltage category: III
[Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit
Irms rated making capacity: 1260 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 250 A 40 °C - 10 min for power circuit550 A 40 °C - 1 min for power circuit950 A 40 °C - 10 s for power circuit1100 A 40 °C - 1 s for power circuit
Associated fuse rating: 250 A gG at 200 A gG at
Average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1
Electrical durability: 0.8 Mcycles 200 A AC-1 at Ue
Power dissipation per pole: 24 W AC-1
Protective cover: With
Interlocking type: Mechanical
Mounting support: PlateRail
Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
Product certifications: BVCCCCSADNVGLRINAULEACUKCA
Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...2.5 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²solid without cable endPower circuit: connector 1 cable(s) 10...120 mm²flexible without cable endPower circuit: connector 2 cable(s) 10...50 mm²flexible without cable endPower circuit: connector 1 cable(s) 10...120 mm²flexible with cable endPower circuit: connector 2 cable(s) 10...50 mm²flexible with cable endPower circuit: connector 1 cable(s) 10...120 mm²solid without cable endPower circuit: connector 2 cable(s) 10...50 mm²solid without cable end
Tightening torque: Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Operating time: 20...50 ms closing6...20 ms opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 8000000 cycles
Maximum operating rate: 2400 cyc/h 60 °C
Coil technology: Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits: 0.3...0.5 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.15 Uc (-40...55 °C):operational AC 50/60 Hz1...1.15 Uc (55...70 °C):operational AC 50/60 Hz
Inrush power in VA: 280...350 VA 60 Hz cos phi 0.8 (at 20 °C) 280...350 VA 50 Hz cos phi 0.8 (at 20 °C)
Hold-in power consumption in VA: 2...18 VA (at 20 °C) cos phi 0.3 60 Hz2...18 VA (at 20 °C) cos phi 0.3 50 Hz
Heat dissipation: 3...8 W at 50/60 Hz
Contact compatibility: M14
Compatibility code: LC2D